OPERATORS MANUAL FOR THE LH 665 VRT SERIAL APPLICATION CONTROL LH No. 020-801-UK Version 1.00 LH Technologies Denmark ApS Mølhavevej 2 9440 Aabybro Denmark Tel. +45 9696 2500 Fax. +45 9696 2501 Internet: http://www.lh-agro.
1 INTRODUCTION 2 GENERAL OPERATION 3 APPLICATION CONTROL, OPERATION 4 APPLICATION CONTROL, ENCODE & CALIBRATION 9 DGPS 11 DATA CARDS AND DATA MANAGEMENT 12 INDEX
Introduction INTRODUCTION ..............................................................................................................1.3 MACHINE SETTING CHART ...........................................................................................1.
INTRODUCTION 1.
LH 665 VRT OPERATORS MANUAL INTRODUCTION INTRODUCTION Congratulations on purchasing the LH 665 advanced DGPS computer. The LH 665 is an advanced and reliable product, which, - if used in accordance with this manual – will prove to be a reliable tool for many years to come. Your new LH 665 is designed to be user friendly, which makes operation easy – in the form of a large screen, and clearly marked back-lit keys.
INTRODUCTION LH 665 VRT OPERATORS MANUAL We have endeavoured to deliver a fault free product. To ensure optimal use of the equipment we ask that great attention be paid when reading the manual. We are more than happy to help should any queries arise, both when the product is used for the first time and at any later date. Regarding responsibility for use of the product we refer to our sales and delivery terms especially paragraph 7, which follows: 7. 7.2 Product usage.
LH 665 VRT OPERATORS MANUAL INTRODUCTION MACHINE SETTING CHART Machine setting chart: Dealer: Fitting date: (Not encoded) Machine type: (Not encoded) Monitor –serial number: Box calibration: GPS Check Sum OFF Volt calibration: Primary speed sensor GPS Controller make: WHEEL Controller model: Secondary speed sensor ! Ensure that the above settings are encoded before work commences. LH AGRO 1.
INTRODUCTION 1.
General operation OVERVIEW ......................................................................................................................2.2 OPERATING THE LH 665 ................................................................................................2.3 ON/OFF SWITCH (POS. 1)......................................................................................2.3 AREA OVERRIDE SWITCH (POS. 5)......................................................................2.3 THE SCREEN ................
GENERAL OPERATION LH 665 VRT OPERATORS MANUAL OVERVIEW Screen section A 7 1 Screen section B 6 2 5 Screen section C 3 4 Pos. Description 2.2 1 ON/OFF switch. 2 Menu key. 3 Menu selection keys. 4 Function keys. 5 Arrow keys. 6 Area override switch. 7 PCMCIA –drive for data cards.
LH 665 VRT OPERATORS MANUAL GENERAL OPERATION OPERATING THE LH 665 ON/OFF SWITCH (POS. 1) The LH 665 is switched on and off with the switch positioned in the upper left-hand corner. The computer will not react if the computer is switched off by mistake whilst, e.g. copying data until the task is finished. Note! The possibility to make a back up of data to a data card is given every time the LH 665 is switched off.
GENERAL OPERATION LH 665 VRT OPERATORS MANUAL ARROW KEYS (POS. 6) The UP, DOWN, LEFT and RIGHT arrow keys on the right-hand side of the panel are used to select and alter a setting. The right and left arrow keys at the bottom of the panel are used to page through the menu selections and are never used to select or alter a setting. An arrow symbol is displayed in the main operating screen next to the field or the load; this symbol indicates what is altered by pressing the arrow keys. FUNCTION KEYS (POS.
LH 665 VRT OPERATORS MANUAL GENERAL OPERATION MENU SELECTION KEYS (POS. 3) The function of the menu selection keys alters depending on what is being done on the computer. The horizontal arrow keys at the bottom of the panel are used to display more menu options. An arrow displayed over the lower arrow keys indicates that pressing the arrow keys will display more options. LH AGRO 2.
GENERAL OPERATION LH 665 VRT OPERATORS MANUAL NOTES 2.
Application control, operation THE APPLICATION CONTROL PROGRAM ....................................................................3.2 DATA PER FIELD ....................................................................................................3.2 OPERATION.....................................................................................................................3.3 SETTING THE LH 665 TO APPLICATION CONTROL ............................................3.3 DEFINING FIELDS BEFORE START .........
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL IMPORTANT Correct encodement and calibration of the LH 665 are essential before correct operation of the following functions. The procedure for encoding and calibration of the LH 665 are described in the respective chapters in this operator’s manual.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION OPERATION SETTING THE LH 665 TO APPLICATION CONTROL The LH 665 may need setting up for application control. The following procedure sets the computers “operating mode”.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL DEFINING FIELDS BEFORE START It is practical to encode all fields (with names if required) before work commences. Field numbers are controlled by the LH 665 and are shown on the upper left-hand side of the display (screen section A) (F1:, F2:,etc). To the right of the field number a name of max. 8 characters can be encoded (i.e. F1: TOPFIELD). It is easiest to use the field numbers that are allocated in the farm’s field plans if this is possible.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION STARTING AND NAMING FIELDS Step Key 1 Procedure Press the MENU key until the following menu selection keys appear at the bottom of the display (screen section C): FIELD 2 FIELD LOAD HIDE MAP OPTIONS Press the FIELD key twice to show the following screen: F1: DG ACTIVE FIELD F1: PRESS TO EDIT NAME PRODUCT PRODUCT 1 ACCEPT ACTIVE CONFIGURATION CONTROLLER LH 5000 VIEW CONFIG CHANNEL N/A CANCEL 3 If there is not a rectangular box
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL START NEW LOAD The procedure for starting new loads is almost the same as described above for starting new fields. Step Key 1 Procedure Press the MENU key until the following menu keys are displayed at the bottom of the screen (screen section C).
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION CHANGING BETWEEN THE ENCODED FIELD AND LOAD NUMBERS Small arrows are shown to the left of the field/load number (screen section A). The field numbers can be paged through if the arrows are to the left of the field number. If however the arrows are to the left of the load number then paging though the loads is possible.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL MARKERS The internal markers in the LH 665 are used together with DGPS positions to mark positions in the field whilst working, i.e. wet areas, weeds, stones, etc.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION THE CONNECTION BETWEEN FIELD AND LOAD KEYS The following example shows how, amongst others, the total weight shown is affected when the LOAD key is pressed or not: Step Key Procedure 1 Press on of the four FUNCTION keys to highlight a section on the screen. 2 Whilst the section is highlighted press the lower ARROW keys until the WEIGHT key is shown, then press this key.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL FUNCTION KEYS All function keys are displayed in the following manner: Step Key Procedure 1 Screen section B is split up in four sub-sections. Each subsection has a corresponding function key to the right of the screen. Press one of the function keys to highlight one of the subsections. 2 Pressing the lower ARROW keys whilst the sub-section is highlighted displays the available function keys.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION WORKING WIDTH Step Key 1 SWATH Procedure X.XX M The present working width in metres sent from the implement controller. Press the lower RIGHT ARROW key to display more functions. TOTAL UNITS Step Key 1 TOTAL UNITS Procedure XXXXX units Total units for the present field or load. GROUND SPEED Step Key 1 GROUND SPEED Procedure XX.X km/hr The actual speed displayed in kilometres per hour. AREA PER HOUR Step Key Procedure 1 XX.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL TGT FILE RATE Step Key 1 TGT FILE RATE Procedure XX.X Units/ha The application rate as defined by the target file. This function can be used if the target rate has been set to manual and the rate from the file is required to be seen. GPS INFORMATION Step Key Procedure 1 This function presupposes that GPS equipment is connected. SAT X The number of satellites that positional signals are being received from. FRQ X.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION Press the lower RIGHT ARROW key to display more functions. ELEVATION Step Key 1 ELEV Procedure This function presupposes that GPS equipment is connected. XXX M The height above sea level displayed in metres. CARD INFORMATION Step Key 1 CARD INFO Procedure XX.X % SPACE FREE The logging time in percent remaining on the data card. DATE/TIME Step Key 1 DATE TIME Procedure DATE XX/XX/XXXX The present date. TIME XX:XX The present time.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL LOAD NAME Step Key Procedure 1 XXXXXXXX The selected load’s name. LOAD NAME LIGHT BAR PASS NUMBER Step Key Procedure 1 X A-B The present pass number. LIGHTBAR PASS # MAP ZOOM 3.14 Step Key Procedure 1 XXX m When in automatic zoom, the map on the screen will automatically zoom in or out to fill as much of the screen as possible. Pressing the RIGHT arrow key allows for manual zoom of the map.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION DIAGNOSTICS It is possible to see various information in the diagnostic menus for faultfinding purposes. Each diagnostic menu can be left by pressing the EXIT key. The displayed information and what it can be used for is described in the chapters that concern the information. Step Key 1 Procedure Press the MENU key until the following menu selection keys are displayed (screen section C): CAL.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL SENSOR DIAGNOSTICS Step Key Procedure 1 Press the SENSOR key to display the following: SENSOR SENSOR DIAGNOSTICS Flow rate X.XXXX uns/sec Ground speed X.X km/hr Master/Drive A Switch X.XXX volts EXIT GPS DIAGNOSTICS More information about the following two diagnostic menus can be found in the DGPS chapter in this manual.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, OPERATION RAW NMEA Step Key Procedure 1 Press the RAW NMEA key to display the following: RAW NMEA NMEA DIAGNOSTICS DG Valid GGA and VTG strings… $GPGGA, 162021.00, 4849.91914,N, 01112.1394 $GPVTG, 178,T,178, M, 006.46, N, 011.97, K*44 EXIT GGA and VTG strings are not shown if a LH ADD-ON GPSmodule is fitted, as the positional signals from these modules use a different format. LH AGRO 3.
APPLICATION CONTROL, OPERATION LH 665 VRT OPERATORS MANUAL NOTES 3.
Application control, Encode & calibration ENCODE ..........................................................................................................................4.2 ENCODE MENUS/VALUES .....................................................................................4.2 CREATING A CONTROLLER FOR APPLICATION CONTROL ..............................4.3 ADVANCED SETTINGS ......................................................................................4.5 APPLICATION CONTROL SETUP ..............
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL ENCODE The necessary values for application control are encoded in the following menus. ENCODE MENUS/VALUES All encodements are selected as follows (presupposes APPLICATION CONTROL is selected under Operating Mode as described on page 3.3): Step Key Procedure Press the MENU key until the following menu selection keys are displayed at the bottom of the screen (screen section C): 1 CAL 2 3 SETUP SETUP DIAG Press the SETUP key.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION CREATING A CONTROLLER FOR APPLICATION CONTROL The following procedure should be followed to "create" an implement controller in the LH 665: Step Key 1 Procedure Press the MENU key until the following menu selection keys appear at the bottom of the display (screen section C): CAL 2 SETUP APP RATE CONFIG 4 CREATE NEW DIAG Press the SETUP key to display the following: APP RATE CONFIG 3 SETUP MARKS CARD LOAD Press the APP RATE
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL Units: Select the units to be used in the main operating screen. If the unit of measure to be used is KG, it is necessary to select another unit of measure, return to the main operating screen, then return back to setup and alter the unit of measure to KG. This will be fixed in later version. Ground Speed Sensor: As the LH 665 is not fitted with any wheel sensor GPS must be selected as the Ground Speed Sensor.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION ADVANCED SETTINGS Target Rate Outside Field: The default setting is Zero. This setting is used to determine what rate should be applied if the implement is outside the field boundary (from the target file). When the default setting (Zero) is used and the implement is not in the field boundary, the application rate will be set to 0.
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL SETUP Step Key 1 APP RATE CONFIG Procedure Press the APP RATE CONFIG key and this screen is displayed: APP RATE CONFIG PRODUCT CONTROLLER CHANNEL PRODUCT 1 LH 5000 N/A EDIT SETTINGS 2 DELETE EXIT Highlight the controller that is to be encoded using the ARROW UP/DOWN keys.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION MARKER SETUP Step Key 1 MARKS Procedure Press the MARKS key and the following is displayed: MARKER SETUP MARK NAME TYPE MARK 1 Stones SPOT MARK 2 Weeds CONTINUOUS MARK 3 Draining CONTINUOUS MARK 4 Other EDIT NAVN 2 3 EDIT NAME EDIT TYPE ACCEPT 5 LH AGRO EXIT Highlight the marker to be encoded with the ARROW UP/DOWN keys.
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL DATA CARD SETUP As many data card and data management functions are the same for all operating modes in the LH 665, the functions are described in the DGPS and DATA CARD AND DATA MANAGEMENT chapters in this manual.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION CONSOLE SETUP Step Key 1 CONSOLE Procedure Pressing the CONSOLE key displays this screen: CONSOLE SETUP Operating Mode APPLICATION RATE Day/Month/Year 3/10/2000 Time 14:00 Serial number 9900085 Box cal 774 Voltage cal 487 GPS Check Sum OFF Field marker input INTERNAL EPROM Language English EDIT 2 3 4 5 EXIT Highlight the setting to be changed using the ARROW UP/DOWN keys.
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL GPS Check Sum: If the DGPS receiver sends a “check sum” then set this encodement to ON. The standard setting is OFF. Field marker input: Select whether the internal markers are used (select INTERNAL) or whether an external marking module is used (select EXTERNAL). EPROM language: Select the operating language of the LH 665.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION GPS SETUP This key has no function unless an ADD-ON GPS model 3000, 3050, or 3100 is connected to the LH 665. If such a module is connected, please read the DGPS chapter. Leave this menu using the EXIT key. MAP SETUP Step Key 1 MAP Procedure Press the MAP key to display this screen: MAP SETUP Coverage Map ON Boundary Map ON Target Map ON EDIT 2 3 4 5 EXIT Highlight the setting to be changed using the ARROW UP/DOWN keys.
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL CALIBRATION These menus allow calibration of the functions that are necessary for application control. THE CALIBRATION MENUS All the calibration menus are selected as follows (presupposes APPLICATION RATE is selected as the operating mode as described on page 3.3).
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION FORWARD SPEED This calibration is for the secondary speed sensor only, which is not fitted as standard. Step Key 1 DISTANCE Procedure Press the distance key and the following is displayed: DISTANCE CALIBRATION: SELECT SENSOR: WHEEL ENTER DISTANCE 2 Select which sensor the LH 665 receives the secondary speed signal from (normally WHEEL, see the encodement chapter).
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL FAULTFINDING Fault Cause Solution The application rate on the implement controller =0: No connection between the LH 665 and the implement controller. Check the connection between the LH 665 and the implement controller. The LH 665 is receiving no DGPS signals. See "No DGPS signal (D or G not displayed)" on page 4.15. The implement is outside the If the implement is outside field boundary.
LH 665 VRT OPERATORS MANUAL APPLICATION CONTROL, ENCODE & CALIBRATION Fault Cause Solution Nothing is shown on the display: The main cable to the LH 665 is not connected or damaged Check that the main cable is connected and not damaged. An external unit, i.e. a DGPS Disconnect all external units receiver is connected and switch the LH 665 on. If incorrectly. the display on the LH 665 works then check the connections to the external unit.
APPLICATION CONTROL, ENCODE & CALIBRATION LH 665 VRT OPERATORS MANUAL NOTES 4.
DGPS DGPS OPERATION..........................................................................................................9.2 DGPS STATUS ON THE SCREEN..........................................................................9.2 GPS DIAGNOSTICS ................................................................................................9.3 RAW NMEA..............................................................................................................9.4 DGPS ENCODEMENT ..........................
DGPS LH 665 VRT OPERATORS MANUAL DGPS OPERATION This chapter describes operating the LH 665 in conjunction with DGPS for yield logging, field boundary measurement and application rate control. There are many ways to show DGPS information in the LH 665 and they are described here, as these are common for all operating modes. DGPS STATUS ON THE SCREEN The current DGPS status is shown in the top right corner of the display, if logging positional data has been selected.
LH 665 VRT OPERATORS MANUAL DGPS GPS DIAGNOSTICS Step Key 1 Procedure Press the menu key until the following menu selection keys are displayed at the bottom of the screen (screen section C): CAL 2 DIAG Press the DIAG key to display the following: DIAG 3 GPS DIAG SETUP SENSORS GPS RAW NMEA Pressing the GPS key displays the following: GPS DIAGNOSTICS UTC TIME 16:18:02 Latitude 04850.1417 N Longitude 01112.1672 E Elevation 498 m GPS speed 0.
DGPS LH 665 VRT OPERATORS MANUAL Differential Status: ON or OFF shows whether differential signals are being received or not. Beacon/Sat. Frequency: Displays the frequency that differential signals are being received from when beacon or geo-stationary differential receivers are used. Differential SNR: The Signal to Noise Ratio shows the strength of the differential signal in relation to background interference. A suitable SNR is between 10 to 18 (the higher the better).
LH 665 VRT OPERATORS MANUAL DGPS DGPS ENCODEMENT There are some things that must be set up before the LH 665 can log positional data to a data card. These settings are the same for all operating modes and we refer to the DATA CARD chapter in this operator’s manual. GPS SETUP If an ADD-ON GPS model 3000, 3050 or 3100 is fitted there are some encodements needed for correct operation.
DGPS LH 665 VRT OPERATORS MANUAL BEACON DIFFERENTIAL Selecting this allows encodement of the beacon receiver (only available if an ADDON GPS module is fitted). The beacon receiver can be encoded as to how it searches for differential signals. The three methods are selected thus: Step Key Procedure Highlight BEACON DIFFERENTIAL using the ARROW UP/DOWN keys.
Data cards and data management DATA CARDS.................................................................................................................11.2 DATA CARD SET-UP.............................................................................................11.2 USING DATA CARDS ....................................................................................................11.4 THE FIRST TIME A DATA CARD IS USED ...........................................................11.4 DATA CARD TYPES...
DATA CARDS & DATA MANAGEMENT LH 665 VRT OPERATORS MANUAL DATA CARDS This chapter discusses all data card related functions found in the LH 665. This chapter is for all operating modes as all data card functions are almost the same for all operating modes DATA CARD SET-UP The LH 665 must be set-up to log positional data to a data card. Step Key 1 Procedure Press the MENU key until the following menu selection keys are shown at the bottom of the display (screen section C): CAL.
LH 665 VRT OPERATORS MANUAL DATA CARDS & DATA MANAGEMENT Logging device: Select whether yield and positional data is to be written directly to a data card if GPS equipment is connected (select MEMORY CARD) or if no data logging if no GPS equipment is connected (select NONE). Logging interval: This setting determines how often yield and positional data is written to the data card. The interval to select depends on the PC program being used to create field maps.
DATA CARDS & DATA MANAGEMENT LH 665 VRT OPERATORS MANUAL USING DATA CARDS THE FIRST TIME A DATA CARD IS USED Insert the data card in the LH 665 before the unit is switched on. The LH 665 automatically determines the data card type. If the data card being used is different than the one supplied with the LH 665 then the procedure is as follows: Step Key Procedure 1 Switch the LH 665 off. 2 Insert the data card and switch the LH 665 on again.
LH 665 VRT OPERATORS MANUAL Step Key 6 7 DATA CARDS & DATA MANAGEMENT Procedure Select the data card size using the ARROW UP/DOWN keys. ACCEPT Press the ACCEPT key. DATA CARD TYPES There are two data card types that are compatible with the LH 665: • LH Flash data card 32MB (LH no. 904-665RC). This data card is supplied with the LH 665. • LH SRAM data card 1MB (LH no. 904-565).
DATA CARDS & DATA MANAGEMENT LH 665 VRT OPERATORS MANUAL AUTOMATICALLY CREATING NEW LOG FILES FOR SRAM DATA CARDS The following procedure is for when the LH 665 is switched on for the first time each day: Step Key Procedure 1 Switch the LH 665 on with the data card inserted. 2 After starting the following is displayed: SELECT LOG FILE Log file 99042202.
LH 665 VRT OPERATORS MANUAL Step Key 5 ERASE DATA CARDS & DATA MANAGEMENT Procedure Pressing the ERASE key deletes the data on the card and displays the following screen: CREATE LOG FILE A new log file must be created for 22/4/1999 to log data New log file: 99042201.YLD ACCEPT 6 ACCEPT CANCEL Press the ACCEPT key and a new file for the day is created. KG CALIBRATION AND DATA LOGGING TO A CARD It is possible to copy the memory to a data card when the LH 665 is switched off.
DATA CARDS & DATA MANAGEMENT LH 665 VRT OPERATORS MANUAL SHOW ALL FILES Step Key 1 SHOW ALL FILES Procedure Shows all files on the data card. It is possible to page through the files using the ARROW UP/DOWN keys. ERASE ALL Step Key 1 ERASE ALL Procedure Removes all files found on the data card.
LH 665 VRT OPERATORS MANUAL DATA CARDS & DATA MANAGEMENT LOG FILE All files on the data card are shown when EDIT is selected for log file under CARD SETUP; it is also possible to create a new file. CHANGING THE LOG FILE Step Key 1 ACCEPT Procedure The file to be logged to can be selected using the ARROW UP/DOWN keys. CREATE FILE Step Key 1 CREATE FILE Procedure A new log file is created when the CREATE FILE key is pressed. FILE NAMES YIELD FILES The LH 665 always names log files with the suffix YLD.
DATA CARDS & DATA MANAGEMENT LH 665 VRT OPERATORS MANUAL UPGRADING THE LH 665 The operating software for the LH 665 is under constant development. It is possible to upgrade the LH 665 via a data card, or via a PC connection, which means that the LH 665 can be upgraded with out removing the monitor. The procedure for upgrading the LH 665 via a data card is as follows: Step Key 1 2 SHOW FILES Procedure Insert the data card that contains the upgrade file and switch the LH 665 on. Press the SHOW FILES key.
Index INDEX.............................................................................................................................12.
INDEX LH 665 VRT OPERATORS MANUAL INDEX -A- Copy to card ......................................11.7 Actual rate..........................................3.10 Copy to file.........................................11.8 Actual rate scale factor ........................4.4 Coverage map ...................................4.11 Actual rate units ...................................4.5 Create file ..........................................11.9 Advanced settings ...............................4.
LH 665 VRT OPERATORS MANUAL INDEX Full swath.............................................4.4 Menu selection keys ............................2.5 Function keys.......................................2.4 -N- -G- Navigation files ..................................11.9 GPS Diagnostics..........................3.16;9.3 NMEA Messages (Add-On GPS only) .9.5 GPS Information ................................3.12 NMEA Strings ......................................9.4 GPS Setup...............................
INDEX LH 665 VRT OPERATORS MANUAL Target map ........................................4.11 Total units ..........................................3.11 Target rate .........................................3.10 -U- Target rate increment...........................4.4 Units.....................................................4.4 Target rate outside field boundary .......4.5 Upgrading the LH 665......................11.10 TGT File rate......................................3.12 Using load numbers........
LH 665 VRT OPERATORS MANUAL INDEX NOTES LH AGRO 12.
INDEX 12.