IC18 SPRAYER JOB COMPUTER U S E R Software version 1.
COPYRIGHTS © 2012 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies. TRADEMARKS Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organizations.
ISOBUS Job Computer : IC18 Sprayer Table of Contents CHAPTER 1– PRODUCT OVERVIEW 1 OPTIONAL SYSTEM COMPONENTS 2 CONFIGURATIONS 4 7 APPLICATION MODE 8 PAGE LAYOUT AND NAVIGATION 9 Home Screen................................................................................................................................ 9 Transport Mode............................................................................................................................ 9 Operation Mode.....................
ISOBUS Job Computer : IC18 Sprayer Time Counter.................................................................................................................... 20 Export Counters.............................................................................................................................................21 JOB PARAMETERS 22 Active Trip Counter........................................................................................................... 22 Preset Application Rates...........
ISOBUS Job Computer : IC18 Sprayer Manual Calibration............................................................................................................ 32 Automatic Calibration........................................................................................................ 32 Alarm Configurations...................................................................................................................................33 CAN Speed Source Timeout........................................
ISOBUS Job Computer : IC18 Sprayer Target Rate Percentage Increase/Decrease..........................................................................................49 Regulation Valve Manual Open/Close...................................................................................................49 Target Rate.......................................................................................................................................................50 With Switchbox.............................
ISOBUS Job Computer : IC18 Sprayer CHAPTER 1– PRODUCT OVERVIEW 98-05204 R1 US 1 APPENDIX OPERATION SETUP GETTING STARTED OVERVIEW Congratulations on the purchase of your new IC18 ECU built on the ISOBUS architecture. This IC18 unit has the capability of either sprayer or NH3 control when integrated into the implement of either capability. When used within the guidelines of this manual, the IC18 controller will be a reliable application tool. This manual covers the Sprayer functions of the IC18 ECU.
ISOBUS Job Computer : IC18 Sprayer OPTIONAL SYSTEM COMPONENTS Matrix 570VT The Matrix 570VT is a simple to operate, ISOBUScertified 5.7″ (14.5 cm) color touch screen display suitable for bright daylight and nighttime operation Figure 1-2: Matrix 570VT OVERVIEW Switchbox GETTING STARTED Manual section control with remote master capibility. The switchboxs are available in two configurations.
ISOBUS Job Computer : IC18 Sprayer BoomPilot Electronic Control Unit for IC18 98-05204 R1 US 3 APPENDIX OPERATION SETUP GETTING STARTED OVERVIEW BoomPilot (automatic boom section control) is possible in combination with software built into the IC18 Sprayer/NH3 Electronic Control Unit (ECU). The ECU should be combined with the appropriate cable to interface with your BoomPilot system, spray controller and/or spraying machine for quick and easy installation.
ISOBUS Job Computer : IC18 Sprayer CONFIGURATIONS The following diagrams are reflective of typical IC18 Job Computer configurations. Due to the variety of possible configurations, these should be used for reference purposes only.
ISOBUS Job Computer : IC18 Sprayer Figure 1-7: IC18 Sprayer TeeJet Retro Kit to Matrix 570 VT Harnessing.
ISOBUS Job Computer : IC18 Sprayer OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 6 www.teejet.
ISOBUS Job Computer : IC18 Sprayer CHAPTER 2 – GETTING STARTED • A firm touch is required when selecting a screen icon. • Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous menu. • The console needs to be cycled off and back on when changing or attaching equipment to the system.
ISOBUS Job Computer : IC18 Sprayer APPLICATION MODE The IC18 job computer is programed to be either a sprayer or NH3 applicator. This setting has been established before leaving the factory, but it can be changed after purchase with assistance from TeeJet Technologies Customer Service or your local dealer through the OEM setup menu options. Figure 2-2: Crop Sprayer Cnt 1 470 gal 1.14 ac + 5.0 mph 1 3 11 5% 42 G PA 0 psi Figure 2-3: NH3 Applicator OVERVIEW Cnt 1 0.0 mph 0 lbN 1 3 11 0.
ISOBUS Job Computer : IC18 Sprayer PAGE LAYOUT AND NAVIGATION The Master Screen gives access to the systems currently available on your VT. From the Master Screen, the Home Screen gives access to the IC18’s available functions. Home Screen The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup. Figure 2-4: Home Screen - Crop Sprayer Mode Operation Mode Regulation Mode Current selection, Auto/Manual, is highlighted with a green dot.
ISOBUS Job Computer : IC18 Sprayer Operation Mode Information on the Operation screen will vary depending on the parameters set by the user and the OEM. Figure 2-6: Operation Mode Screen Overview Applied Area Applied Volume Active Trip Count Number Alert Warning Cnt 5 Speed/Application Information 5.2 Remaining Tank Contents mph Density Flow Based or Pressure Based 4070 gal Cnt Target Rate Indicator Application Rate Target Rate Percentage Increase/Decrease 1.14 ac 5 5.
ISOBUS Job Computer : IC18 Sprayer Main Setup Mode The main setup menu contains six options. Each of these options either directly access settings or additional menus.
ISOBUS Job Computer : IC18 Sprayer Main Setup Menu Icons and Section Overviews Figure 2-8: Enter Selection Screens Selection Slide Bar with Decrease One Selection and Increase One Selection Arrows Accept Key Escape Key Number Pad Close Number Pad Key Range Maximum Range Minimum Zoom In Key OVERVIEW Zoom Out Key Open Number Pad Key GETTING STARTED Available Selections Up One Selection SETUP Accept Key Escape Key OPERATION Down One Selection APPENDIX 12 www.teejet.
ISOBUS Job Computer : IC18 Sprayer Description Accept Key Accepts the new selection Close Number Pad Key Minimizes the number pad Decrease One Selection Arrow Decreases the setting Down One Selection Arrow Highlights the selection below Escape Key Escapes without saving changes Increase One Selection Arrow Increases the setting Number Pad Use the numbers to set the selection value Open Number Pad Key Maximizes the number pad Selection Displays the current or new selection Slider Slide to
ISOBUS Job Computer : IC18 Sprayer OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 14 www.teejet.
ISOBUS Job Computer : IC18 Sprayer CHAPTER 3 – MAIN SETUP IN SPRAYER MODE Main Setup Mode configures the Counters, Job Parameters, Machine, User Interface, Communication and Help options. NOTE: The menu structure on your display might vary from the one displayed in this User Manual depending on the virtual terminal being used.
ISOBUS Job Computer : IC18 Sprayer Main Setup Screen OVERVIEW GETTING STARTED SETUP OPERATION NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE KEY to escape without saving settings and return to the previous menu. To access the Main Setup screens: 1. Select IC18 SPRAYER KEY from the Master Screen. 2. Select MAIN SETUP SCREEN KEY from the Home Screen. 3.
ISOBUS Job Computer : IC18 Sprayer Master Screen 98-05204 R1 US 17 APPENDIX OPERATION SETUP The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup. • To view the Home Screen, select HOME KEY in the top right corner of any screen. Figure 3-3: Home Screen Home Key on Main Setup Screen GETTING STARTED Home Screen OVERVIEW The Master Screen gives access to the systems currently available on your VT.
ISOBUS Job Computer : IC18 Sprayer COUNTERS The Counters Menu provides an overview of various system counters including Trip Counters, Campaign Counters and Total Counters. From this screen one can also Export Counters. | Counters | Job Parameters MAIN SETUP MENU | Machine | User Interface | Communication Trip Campaign Total Export Counters OVERVIEW 1. From the Main Setup Screen , select COUNTERS. Figure 3-4: Counters 2.
ISOBUS Job Computer : IC18 Sprayer Trip Counters Trip Counters displays information regarding area, distance, time and amount applied. The trip that is active is displayed/active on the Operations Screen. Figure 3-5: Trip Counters Menu Active Trip Counter One of up to ten (10) Active Trip Counters can be selected to view the desired trip information. The trip that is “active” is displayed/active on the Operation Screen. • To select the Active Trip Counter, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer Campaign Counters Campaign Counters display information regarding area, Figure 3-7: Campaign Counters amount applied and time for all trips. • To clear the Campaign Counters, select TRASH CAN KEY . A confirmation screen will be displayed. Area Counter Displays total applied coverage area for all trips. Volume Counter Displays total volume of material applied during all trips.
ISOBUS Job Computer : IC18 Sprayer Export Counters Export Counters allows counter information to be exported Figure 3-10: Export Counters in HTML or CSV format. HTML files can be viewed from an internet browser. CSV files can be viewed as Excel sheets. • To export a HTML file, select HTML KEY .A confirmation screen will be displayed. • To export a CSV file, select CSV KEY .A confirmation screen will be displayed. For data transfer, an optional cable is required.
ISOBUS Job Computer : IC18 Sprayer JOB PARAMETERS Job Parameters configures application settings. Options include Active Trip Counter, Preset Application Rates and Nozzle. | Counters MAIN SETUP MODE MENU STRUCTURE | Job Parameters 1. From the Main Setup Screen PARAMETERS. | Machine , select JOB | User Interface | Communication | Help Figure 3-12: Job Parameters NOTE: Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting.
ISOBUS Job Computer : IC18 Sprayer MACHINE Machine configures machine settings. Options include Filling, Operation, Implement Parameters, Calibrations, Alarm Configurations and OEM.
ISOBUS Job Computer : IC18 Sprayer Filling Filling establishes the amount of material remaining in the tank and the density of that material. Different options will be available depending on if a tank sensor is installed. NOTE: The size of the tank is established in the OEM menu. This is the number that will repopulate when the Full Tank Key is pressed. Figure 3-14: Filling Actual Content Actual Content displays the current volume of content in the tank. The volume can be manually adjusted.
ISOBUS Job Computer : IC18 Sprayer Operation Operation establishes Application Rate Step, Speed Source and Simulated Speed. Figure 3-15: Operation Application Rate Step Application Rate Step is the percent of increase/decrease “boost” of the active application rate at which the product is being applied. • To select the percentage, use the number pad or slide bar. Speed Source Speed Source selects whether to base the machine’s speed on input from the CAN, an Implement or a Simulated source.
ISOBUS Job Computer : IC18 Sprayer Implement Parameters Figure 3-17: Implement parameters Implement Parameters establishes the following: ►Section Width – sets the spraying width during application. ►Nozzle Preset Setup – where up to five (5) sets of nozzle options can be established to set the nozzle type, size, low/high pressure limit, reference flow and reference pressure. ►Regulation Parameters – where adjustments to the valve calibration, nozzle spacing and regulations mode can be established.
ISOBUS Job Computer : IC18 Sprayer Nozzle Preset Setup Nozzle Preset Setup establishes up to five (5) sets of nozzle options setting the nozzle type, size, low/high pressure limit, reference flow and reference pressure. Figure 3-19: Nozzle Preset Setup Nozzle Preset Each one of up to five (5) Nozzle Presets can be selected to establish different sets of nozzle options. • To select the Nozzle Preset set, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer Low Pressure Limit Low Pressure Limit establishes the limit for the lowest allowed operating pressure for the selected nozzle type. • To select the Low Pressure Limit, use the number pad or slide bar. High Pressure Limit High Pressure Limit establishes the limit for the highest allowed operating pressure for the selected nozzle type. • To select the High Pressure Limit, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer Valve Calibration, Fine Fine regulation value calibration allows you to regulate the setting of the regulating valve to accommodate different application needs. Operating conditions may necessitate a higher or lower response setting for the regulating valve. This digit adjsuts the setting for the fine tune adjustment in relation to a small percentage close to the target application rate.
ISOBUS Job Computer : IC18 Sprayer If your system is plumbed in a throttling mode, start with a valve setting number of 3 and adjust the number according to your application requirements. Low flow situations will require a slower response time. Adjusting agitation volumes to accommodate the regulating valve to work in a more fully open position allows for a faster response time, with little to no searching. NOTE: This setting value can be adjusted to optimize system performance.
ISOBUS Job Computer : IC18 Sprayer Calibrations Calibrations establishes either manual or automatic settings of the sensors. NOTE: For specific calibration options to appear, a specific sensor needs to be installed. Sensor availability is activated on the Sensor Presence screen in the OEM section. Figure 3-24: Calibrations Implement Speed Sensor The Implement Speed Sensor establishes the wheel pulses over a specified distance. This value can be established manually or calibrated automatically.
ISOBUS Job Computer : IC18 Sprayer Flow Sensor The Flow Sensor establishes the pulses per gallon/liter. This value can be established manually or calibrated automatically. Figure 3-26: Flow Sensor Manual Calibration Manual calibration establishes the calibration and limits based on user entered values. • To select the Flow Meter Calibration, use the number pad or slide bar. • To select the Low Limit, use the number pad or slide bar. • To select the High Limit, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer Alarm Configurations Alarm Configurations establishes alarms on or off as well Figure 3-27: Alarm Configurations as sets their trigger level. CAN Speed Source Timeout CAN Speed Source Timeout establishes how long the system can operate after the CAN speed source input is lost before the alarm is triggered. • To select the CAN Speed Source Timeout time, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer OEM OVERVIEW GETTING STARTED SETUP The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment. To obtain an access code, contact your local dealer or TeeJet Technologies Customer Service. To access the OEM screens: Figure 3-28: Machine to OEM 1. From the Main Setup Screen , select MACHINE. 2. Select OEM. 3. Select the Access Code Entry Box to the right of the menu option. 4.
ISOBUS Job Computer : IC18 Sprayer USER INTERFACE User Interface allows the operator to select the system virtual terminal (VT), switchbox pairing, BoomPilot ECU pairing and soft key numbering as well as view serial numbers and ECU identification number. | Counters MAIN SETUP MODE MENU STRUCTURE | Job Parameters 1. From the Main Setup Screen select USER INTERFACE.
ISOBUS Job Computer : IC18 Sprayer • To set the BoomPilot ECU pairing, select an option from the drop down menu or use the UP/DOWN ARROWS to highlight the option. OVERVIEW Currently Paired With Information Displays the current ECU ID numbers for a paired switchbox or BoomPilot ECU. • If no switchbox or BoomPilot ECU is on the system, "none" will be shown. • If a specific switchbox or BoomPilot ECU has been chosen to be paired with and it is not available on the system, "none" will be shown.
ISOBUS Job Computer : IC18 Sprayer COMMUNICATION Communication establishes the IC18's ability to communicate with an external computer. MAIN SETUP MODE MENU STRUCTURE | Communication | Help OVERVIEW Figure 3-32: Communication GETTING STARTED , | User Interface SETUP 1. From the Main Setup Screen select COMMUNICATION.
ISOBUS Job Computer : IC18 Sprayer HELP The Help menu allows the operator to choose between Diagnostics and the display of information about serial number, CAN BUS information, etc. These menus are typically accessed upon Customer Service personnel request only. | Counters MAIN SETUP MODE MENU STRUCTURE | Job Parameters | Machine | User Interface | Communication | Help Diagnostic About 1. From the Main Setup Screen , select HELP. 2.
ISOBUS Job Computer : IC18 Sprayer Diagnostic Figure 3-34: Diagnostic Diagnostic is used to troubleshoot input/output of the controller (sensor or actuator). ►Test Input – displays the input high and low values on the installed sensors. ►Test Output – sets the Liquid Valve PWM Dutycycle percentage as well as if Liquid Valve Direction, Master Valve, Fill Valve and Section Valves 1-9 are on or off. ►VT – provides information regarding the virtual terminal controller.
ISOBUS Job Computer : IC18 Sprayer Test Output Test Output sets the Liquid Valve PWM Dutycycle percentage as well as if Liquid Valve Direction, Master Valve, Fill Valve and Section Valves 1-9 are on or off. Figure 3-36: Test Output Liquid Valve PWM Dutycycle Liquid Valve PWM Dutycycle is used to test the regulating valve at different percentages of duty cycle. • To set the Liquid Valve PWM Dutycycle, use the number pad or slide bar.
ISOBUS Job Computer : IC18 Sprayer VT Data Figure 3-37: VT Data The Virtual Terminal (VT) menu provides information regarding the virtual terminal controller (i.e., address version, etc.). • If more terminals/controllers are used, switch between these by pressing the GO TO NEXT VT KEY . • Press the DELETE OBJECT POOL KEY to delete saved information on the VT. This forces the VT to upload all information from the IC18 on the next power cycle.
ISOBUS Job Computer : IC18 Sprayer OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 42 www.teejet.
ISOBUS Job Computer : IC18 Sprayer CHAPTER 4 – OPERATION MODE The Operation Screen accesses the working aspects of the IC18 including boom section control, rate control and trip/count/application information. NOTE: Settings are automatically saved when selected. NOTE: The menu structure on your display might vary from the one displayed in this User Manual depending on the virtual terminal being used. Auto/Manual Key on Operation Screen 5 4070 gal 1.14 ac + mph 1 3 11 283 G PA SETUP 5.
ISOBUS Job Computer : IC18 Sprayer OPERATION MODE OVERVIEW Information on the Operation screen will vary depending on the parameters set by the user and the OEM. Figure 4-2: Operation Mode Screen Overview Applied Area Applied Volume Active Trip Count Number Alert Warning Cnt 5 Speed/Application Information 5.2 Remaining Tank Contents mph Density Flow Based or Pressure Based 4070 gal Cnt Target Rate Indicator Application Rate Target Rate Percentage Increase/Decrease 1.14 ac 5 5.
ISOBUS Job Computer : IC18 Sprayer Keys Descriptions Description Home Key Press to return to the Home Screen Start/Stop Key Press to start or stop application Information Key Press to toggle between display modes Boost/Step Percentage Increase/ Decrease Keys Press to establish the required boost percentage step, i.e.
ISOBUS Job Computer : IC18 Sprayer Section and Icon Descriptions Section or Icon Description Job Information This information bar displays the active count number, applied volume and applied area Cnt Count Number Displays the current active trip or job number Applied Volume Displays volume applied for the selected count number Applied Area Displays applied area for the selected count number 1 0 gal 0.
ISOBUS Job Computer : IC18 Sprayer Section or Icon Description Boom Sections Displays the active and inactive boom sections as well as if they are on (spray is blue) or off (spray is gray). NOTE: The color on the boom sections indicates the color of the selected nozzle type. Circulation SC If Circulation is installed and selected in the OEM Menu, “SC” (Semi Circulation) or “CC” (Full Circulation) will be displayed. Displays if the unit is in NH3 mode.
ISOBUS Job Computer : IC18 Sprayer Master Screen The Master Screen gives access to the systems currently available on your VT. • To view the Master Screen options, select MASTER SCREEN KEY in bottom right corner of any screen. Figure 4-3: Master Screen Master Screen Key on Operation Mode Screen Cnt 1 0.0 mph 0 gal 1 3 11 0.00 ac 0 G PA 0 psi OVERVIEW Home Screen GETTING STARTED The Home Screen gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup.
ISOBUS Job Computer : IC18 Sprayer APPLICATION RATE OPTIONS Target Rate Percentage Increase/Decrease Figure 4-5: Target Rate Percentage Increase/ Target Rate Percentage Increase/Decrease Keys Decrease increase/decrease the application target rate per the Cnt 1 0 gal 0.00 ac established percentage set in the Machine Operation setup screen under Application Rate Step. Automatic regulation mode will automatically adjust the application 0.
ISOBUS Job Computer : IC18 Sprayer Target Rate Preset Application Rates define up to five (5) target rates of product being applied per hectare/acre. These settings will set the same for all active trips. Target rates set to “0.0” will not be included in the toggle preset target rate options on the Operation Screen or Home Screen. If a switchbox is being used to control the boom sections, current target application rate can be set on the Operation Screen.
ISOBUS Job Computer : IC18 Sprayer Orange 015 Green 02 Yellow 025 Purple 03 Blue 04 Red 05 Brown 06 Grey 08 White 10 Light Blue 15 Light Green 20 Black 1 0.0 mph 0 gal 1 3 11 0.
ISOBUS Job Computer : IC18 Sprayer On/Off Sections from the Left or Right When a switchbox is not connected for boom section control, booms sections are controlled using the Boom Sections On/Off Keys. Without Switchbox Figure 4-10: Left Off • To adjust the sections on the left, press the LEFT Cnt 1 0 gal BOOM SECTIONS ON/OFF KEYS . • To adjust the sections on the right, press the RIGHT 0.0 1 3 11 BOOM SECTIONS ON/OFF KEYS . mph 0.00 ac 16.
ISOBUS Job Computer : IC18 Sprayer Start/Stop Application When a switchbox is not connected for boom section control, starting/stopping application is controlled using the Start/Stop Key. Without Switchbox • To start or stop the application, press the START/ STOP KEY . Figure 4-13: Spraying Stopped Cnt 5.0 With Switchbox mph If a switchbox is being used to control the boom sections, starting/stopping application will be controlled by the switchbox. Figure 4-15: Operations Screen With Switchbox 0.
ISOBUS Job Computer : IC18 Sprayer Master Stop Key Master Stop Key is used to stop all application, close all Figure 4-16: Spraying In Progress Cnt 1 20 gal 0.25 ac regulation valves and change to manual regulation mode. • To stop all application, close all regulation valves and 5.0 26.7 change to manual regulation mode, press the STOP 1 3 11 mph G PA KEY . This is designed to be like an emergency stop button.
ISOBUS Job Computer : IC18 Sprayer INFORMATION KEY Information Key toggles the Speed/Application Information section on the Operation Screen between the display modes. • Vehicle speed • Volume applied per minute • Projected area per hour to be covered based on current speed, target rate and tank level • Projected total area remaining to be covered based on current target rate and current tank level Figure 4-18: Information Key 0 gal 0 gal 1 ac/h Cnt G PA psi 0 gal 0.0 0 1 3 11 0 GPM Cnt 0.
ISOBUS Job Computer : IC18 Sprayer TRANSPORT MODE While in Transport Mode, all operation functions are locked off and cannot be activated. Transport Mode displays the speed in analogue mode. Figure 4-19: Transport Mode Home Key ►Gives access to the IC18’s available functions: Operation Mode, Transport Mode and Main Setup Speedometer Master Screen Key ►Gives access to the systems currently available on your VT OVERVIEW GETTING STARTED SETUP OPERATION APPENDIX 56 www.teejet.
ISOBUS Job Computer : IC18 Sprayer APPENDIX A - FACTORY SETTINGS & RANGES JOB PARAMETERS Description Factory Setting Range User Setting Active Trip Counter 1 1 - 10 1 2 3 4 5 6 7 8 9 10 #2 #4 Preset Application Rate #5 #5 GETTING STARTED #3 Preset Application Rate #4 Nozzle OVERVIEW #1 Established under Machine--> Implement Parameters--> Nozzle Preset Setup SETUP Preset Application Rate #3 0.0 - 700.6 (US) 0.0 - 6553 0.0 - 583.4 (UK) OPERATION Preset Application Rate #2 0.0 GPA (US) 0.
ISOBUS Job Computer : IC18 Sprayer MACHINE Tank Filling Description Factory Setting Range/Options Actual Content 0 lbN (US) 0 kgN 0 lbN (UK) 0 - 12000 0 - 5443 0 - 12000 Density Water Water Fertilizer Density Factor 6.68 Lb/Gal (US) 0.80 kg/l 8.02 Lb/Gal (UK) 6.68 - 16.69 (US) 0.80 - 2.00 8.02 - 20.04 (UK) Description Factory Setting Range/Options Application Rate Step 5% 1 - 20 Speed Source CAN CAN Implement Simulated Simulated Speed 0.0 mile/h / km/h 0.0 - 99.
ISOBUS Job Computer : IC18 Sprayer Section Width Description Factory Setting Range Section Width 118 in. / 300 cm 1 - 9999 Description Factory Setting Range/Options Nozzle Preset 1 1-5 Nozzle Type General General User Tip Nozzle Size 025 (purple) 01 Orange 015 Green 02 Yellow 025 Purple 03 Blue 04 Red 05 Brown 06 Grey 08 White 10 Light Blue 15 Light Green 20 Black Low Pressure Limit 14 psi 1.0 bar 0 - 369 0.0 - 25.5 High Pressure Limit 58 psi 4.0 bar 0 - 369 0.0 - 25.
ISOBUS Job Computer : IC18 Sprayer Calibrations Implement Speed Sensor Description Factory Setting Range/Options Pulses per Distance 0 0 - 33445 Description Factory Setting Range/Options CAN Speed Source Timeout 4 sec 0 - 999 Active Trip Count Imformtaion Off Off On Tank Content Minimum 0 GAL (US) 0 liters 0 GAL (UK) 0 - 2641 (US) 0 - 9999 0 - 2199 (UK) Description Factory Setting Range/Options Use Perferred VT Off Off On Pair with Switchbox Auto Auto None <> Pair w
ISOBUS Job Computer : IC18 Sprayer APPENDIX B - UNIT SPECIFICATIONS Dimensions 7.5 x 7.25 x 2.375 in 19.05 x 18.42 x 6.03 cm Weight 1.42 lbs / 0.644kg Connector 30 position Cinch pins. A1-K3 Input/Output ISO 11783 (ISOBUS) Power Requirement <9 watts @12 VDC GETTING STARTED 90% non-condensing SETUP -40 to +85°C Humidity OPERATION Operating 98-05204 R1 US 61 APPENDIX Environmental OVERVIEW 30 position Cinch pins.
I C18 S P R AYE R J O B CO M P U T E R U S E R Software Version 1.06 1801 Business Park Drive Springfield, Illinois 62703 USA Tel: (217) 747-0235 • Fax: (217) 753-8426 www.teejet.