Instruction Manual

17
Fieldware
®
Link 4.02
98-05244-EN R1
Figure 39: Machine settings – Straight implement type
TeeJet spreader implement type
NOTE: When loading this profile type onto a console without
a Smartcable or SDM on the system, only values for
Section 1 will be used. All other section or ABSC information
will be retained in the background as unused parts of the
profile.
Loading a spreader implement type onto a console that
has not had the spreader ABSC feature unlocked is not
permitted.
The machine settings for multiple-section spreader
applications are machine dependent. Please consult
with the spreader manufacturer, and not TeeJet, for these
machine specific settings.
Basic properties
►Description – used to enter the name of the machine settings
prole.
►GPS antenna height – used to measure the height of the
antenna from the ground. Range is 0.0 to 10.0 metres.
►Guidance width – used to enter the distance between the
guidelines. Range is 1.0 to 75.0 metres.
►Implement type – used to select Spreader as the layout of
the sections for the applied product location.
►Implement offset direction – direction from the centreline
of the machine to the centre of the implement while facing in
the machine’s forward direction
►Implement offset distance – used to enter the distance
from the centreline of the machine to the centre of the
implement. Range is 0 to 10.0 metres.
►Antenna to disks distance – used to enter the distance
from the GPS antenna to the delivery disks or dispersal
mechanism. Range is 0.0 to 50.0 metres.
►Number of implement sections – used to select the number
of implement sections. When ABSC Enabled is checked,
Smartcable and SDM options are available for editing.
►Tank capacity – used to enter the capacity of the tank
►ABSC enabled – used to enable ABSC (automatic boom
section control) options
Unchecked – single section setup options will be available
(see “ABSC enabled – Single Section Setup” section for
details)
Checked – Smartcable or SDM setup options will be
available
Implement dynamics
►Setup type – used to select TeeJet spreader type
►Delay on time – used to set the time when each section will
switch on when entering an area that has not been applied. If
the application turns on too soon when entering an unapplied
area, decrease the delay on time. If the application turns on
too late, increase the delay on time. Range is 0 to 10 seconds.
►Delay off time – used to set the time when each section will
switch off when entering an area that has been applied. If the
application turns off too soon when entering an applied area,
decrease the delay off time. If the application turns off too
late, increase the delay off time. Range is 0 to 10 seconds.
►Spread offset distance – used to enter the offset distance
from the disks, or dispersal mechanism, to where product
initially hits the ground on section 1. Range is 0.0 to 75.0
metres.