Instruction Manual
13
Fieldware
®
Link 4.02
98-05244-EN R1
ABSC disabled – Single section setup
ABSC disabled or single section setup is used when a Smartcable
or Section Driver Module (SDM) is not on the system. The entire
boom or delivery area is considered to be one section.
NOTE: If a Smartcable or Section Driver Module (SDM) is present,
refer to “Smartcable or Section Driver Module setup” to view
setup steps.
Straight implement type
Basic properties
►Description – used to enter the name of the machine settings
prole.
►GPS antenna height – used to measure the height of the
antenna from the ground. Range is 0.0 to 10.0 metres.
►Guidance width – used to enter the distance between the
guidelines. Range is 1.0 to 75.0 metres.
►Implement type – used to select Straight as the layout of
the sections for the applied product location.
►Implement offset direction – direction from the centreline
of the machine to the centre of the implement while facing in
the machine’s forward direction
►Implement offset distance – used to enter the distance
from the centreline of the machine to the centre of the
implement. Range is 0 to 10.0 metres.
►Boom offset direction – used to select whether the boom is
located in front of or behind the GPS antenna as the vehicle
moves in a forward direction
►Antenna to boom distance – used to enter the distance
from the GPS antenna to the boom. Range is 0.0 to
50.0 metres.
►Number of implement sections – used to select the number
of implement sections. When ABSC Enabled is unchecked,
number of implement sections is set to one implement
section and is unavailable for editing.
►Tank capacity – used to enter the capacity of the tank
►ABSC enabled – used to enable/disable ABSC (automatic
boom section control) options
• Unchecked – single section setup options will be available
• Checked – Smartcable or SDM setup options will be
available (see “ABSC enabled – Smartcable or Section
Driver Module setup” section for details)
Implement dynamics
►Section width (under Spray width in Matrix Pro v2.xx
or Matrix Pro GS v2.xx, or under Application width in
Matrix Pro GS v3.xx) – used to enter the total width of the
implement.
Job specic defaults
There are no available options.
Figure 28: Basic properties
Figure 29: Implement offset distance and direction
Figure 30: Machine settings – Straight implement type