Install John Deere 8xxx
www.teejet.com
4
FieldPilot
®
1. INSTALL SPACERS ON STEERING FLOWMETER SENSOR
Non-ILS only
On non-ILS machines, there will be hydraulic owmeter. The two spacers (G) will be installed on the
owmeter sensor. To gain access to the owmeter sensor the owmeter may need to be partially removed
(depends upon tractor model). First remove the cover from the air cleaner. Disconnect the steel line from
the owmeter and remove the two bolts mounting the owmeter. Then the owmeter may be slid out and
rotated to gain access to its sensor. Using a 4mm hex wrench remove the two screws holding the sensor.
Then use screws (H) to install the spacers (G) under the sensor as shown. Slide the owmeter back into its
mounting location and reinstall the mounting bolts. Then reconnect the steel line to the owmeter.
Figure 1-3: Install Spacers On Steering Flowmeter Sensor
Flowmeter
Remove Bolts
Disconnect Sensor