Install John Deere 8xxx

www.teejet.com
4
FieldPilot
®
1. INSTALL SPACERS ON STEERING FLOWMETER SENSOR
Non-ILS only
On non-ILS machines, there will be hydraulic owmeter. The two spacers (G) will be installed on the
owmeter sensor. To gain access to the owmeter sensor the owmeter may need to be partially removed
(depends upon tractor model). First remove the cover from the air cleaner. Disconnect the steel line from
the owmeter and remove the two bolts mounting the owmeter. Then the owmeter may be slid out and
rotated to gain access to its sensor. Using a 4mm hex wrench remove the two screws holding the sensor.
Then use screws (H) to install the spacers (G) under the sensor as shown. Slide the owmeter back into its
mounting location and reinstall the mounting bolts. Then reconnect the steel line to the owmeter.
Figure 1-3: Install Spacers On Steering Flowmeter Sensor
Flowmeter
Remove Bolts
Disconnect Sensor