Install AgChem 1803 User Manual
www.teejet.com
11
FieldPilot
®
4. PREPARE COUNTERBALANCE VALVE (B) BLOCK
Make sure the valve block is clean and dust free. Work on a clean bench. Remove the plastic plugs and
install the straight ttings (T) in ports C1 and C2. Install the elbow adapter ttings (U) in ports V1 and V2.
Orient the elbow adapters so that they are pointing the opposite direction from the ttings in ports C1 and C2.
Install #8 JIC Run Tee ttings (R) on the straight adapters in ports C1 and C2.
Figure 1-5: Prepare Counterbalance Valve Block
U
U
T, R T, R