FieldPilot
®
4. INSTALL EXCESS FLOW HOSE
Connect hose (L) to adapter (O) installed in the EF port on the FieldPilot Valve. Connect the other end of
this hose to the -10JIC adapter on the hydraulic valve stack left open when the original excess ow hose
was discarded. Take care routing the hose to be sure it is clear of all drive belts and cannot rub on other
components.
Figure 1-7: Install Excess Flow Hose
Hose L for excess ow
Hose L for excess ow
5. INSTALL PRESSURE HOSE
Connect hose (L) to adapter (O) installed in the P port of the FieldPilot valve. Connect the end of the hose
to the EF port of the Priority valve left open when the original excess ow hose was discarded.
Figure 1-8: Install Pressure Hose
Hose L for Pressure
Hose L for Pressure