Quick Reference Guide
S
YSTEM
S
ETUP
M
ODE
The Delivery switch must be off. Press
+
or keys
while simultaneously
pressing the
P
RO
key. Press the
P
RO
key again to enter the System Setup Mode.
Step Display Description My Values
Units
US, INP
Select US or Imperial gallons for your
application units by using
+
or keys.
Proceed to next step with
P
RO
key.
Flow Meter
Pulses
Flow Meter Pulses;
Value from flow meter label. Adjust by
using
+
or keys.
Proceed to next step with
P
RO
key.
Nozzle Spacing
Nozzle (or row) spacing;
Distance between spray nozzles or micro
tubes in inches.
Proceed to next step with
P
RO
key.
Tips per boom
section
SEC
1
# of tips or micro tubes on the machine.
Adjust with
+
or keys.
Proceed to next step with
P
RO
key.
Speed
Calibration
Speed Calibration. Change with + and -, or
to auto calibrate press + and -
simultaneously to clear value, then drive
300 feet and press
P
RO
.
Distance
Counter
Ft
Not a calibration step, but allows you to
measure distance in feet. Press
+
key to
start counting, press
+
key again to stop
counting.
Proceed to next step with
P
RO
key.
Simulated Speed
Enter the desired simulated ground speed
using
+
or keys.
Proceed to next step with
P
RO
key.
Communications
No con
Select the communications mode.
Proceed to next step with
P
RO
key.
Minimum
Pressure
Min prs
Sets the minimum pressure to which the
controller will regulate. The controller will
not regulate below this pressure.
To exit the System Setup mode, press and hold
P
RO
for 3 seconds at any point in
programming process.