844-E Sprayer Control
Step 4 – Measure
Turn controller on and activate pump. Toggle on the Master Boom Switch and the number of boom sections to be measured. Insure that the
pressure at the boom is maintained at 40 psi (2 bar). While spraying press and hold the Program key in. Look at the lower right display to see
if the measured ow matches the calculated ow.
Step 5 – Adjustments
If the measured ow does not match the calculated ow, the ow meter number may need to be adjusted. If the measured ow is higher than the
calculated ow, the ow meter calibration number needs to be decreased. If the measured ow is lower than the calculated ow, the ow meter
calibration number needs to be increased.
Example: Calculated flow is 4.00 GPM (12.9 LPM)
{3.20 Imp GPM}; measured flow is 3.6 GPM
(11.6 LPM) {2.88 Imp GPM}
Decrease the ow meter calibration number by 10%. If original number was 650, enter 585 for this programming value.