Instruction Manual

6. Program
Function Display Possible actions Comments
Access / Exit
Push Pro for 3 seconds
Master must be off
1. Carrier
flowmeter
Car . f l o
w
setu
p
to select another step
Pro to enter carrier flowmeter
calibration (1.1)
Push Pro for 3 seconds to escape
program
1.1
Car . f l o
w
150
p
/l
to modify value
Pro to validate value
Main carrier flowmeter
calibration in pulses/lt
2. Injection
pump
Inj . pump
setu
p
to select another step
Pro to enter calibration (2.1)
Push Pro for 3 seconds to escape
program
2.1 Injection
pump type
Inj . pump
Pist on
2
to modify value
Pro to validate value (2.2)
CLR to escape (2)
Choices are :
Peristaltic
Piston 1 (head)
Piston 2 (heads)
Piston 3 (heads)
Piston 4 (heads)
2.2 Injection
pump
calibration
to modify value
This is the complete
pump calibration (all
heads together.
Inj . pump
6.00
Pro to validate value (2)
CLR to start Autocalibration (see ch. 7)
Units are pulses/ml.
Average value is 3.00 per
head for a piston pump.
3. Prime
calibration
pr im
e
setu
p
to select another step
Pro to enter calibration (3.1)
Push Pro for 3 seconds to escape
program
3.1
Pr im
e
2.000 l
to modify value
Pro to validate value
CLR to start Autocalibration (see ch. 8)
This is the volume that
must be pumped to prime
the system.
026-UK V1.01 18/05/2006 Page 6 of 8