Performance Data Sheet
Performance Data Sheet
TPB9421YAA
General Information
Model TPB9421YAA Refrigerant R-134a
Test Condition ARI Performance Test Voltage 115V ~ 60HZ
Return Gas 18.3°C (65°F) RETURN GAS Motor Type CSIR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 3200 3020 2810 2580 2340 2100 1870
Watts 368 386 401 414 425 434 443
Amps 5.84 5.93 6.01 6.08 6.14 6.21 6.28
20
Lb/h 41.1 40.8 40.0 38.7 37.1 35.4 33.8
Btu/h 3580 3380 3160 2910 2650 2390 2130
Watts 387 405 421 435 448 460 471
Amps 5.95 6.05 6.14 6.22 6.29 6.37 6.45
25
Lb/h 46.1 45.9 45.1 43.8 42.2 40.5 38.7
Btu/h 4010 3800 3550 3280 3000 2710 2430
Watts 407 425 442 458 472 486 499
Amps 6.06 6.16 6.26 6.35 6.43 6.52 6.62
30
Lb/h 51.8 51.7 50.9 49.6 48.0 46.1 44.3
Btu/h 4490 4260 3990 3690 3380 3070 2760
Watts 427 446 463 480 497 513 529
Amps 6.16 6.27 6.38 6.48 6.58 6.68 6.79
35
Lb/h 58.3 58.2 57.4 56.1 54.4 52.5 50.5
Btu/h 5020 4760 4470 4150 3810 3460 3120
Watts 447 467 485 504 522 540 559
Amps 6.27 6.39 6.51 6.62 6.73 6.85 6.98
40
Lb/h 65.5 65.4 64.6 63.3 61.5 59.5 57.4
Btu/h 5600 5310 4990 4640 4270 3890 3510
Watts 468 488 508 528 548 569 590
Amps 6.39 6.53 6.66 6.79 6.91 7.04 7.19
45
Lb/h 73.4 73.3 72.5 71.1 69.3 67.2 64.9
Btu/h 6210 5900 5550 5160 4750 4340 3920
Watts 490 511 531 553 575 597 621
Amps 6.55 6.70 6.85 6.99 7.13 7.27 7.43
50
Lb/h 82.0 81.9 81.1 79.6 77.7 75.5 73.1
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 1.418374E+03 3.380540E+00 3.209162E+00 -2.376364E+00
C2 1.033909E+01 5.913893E+00 6.215832E-02 -6.241870E-02