Datasheet
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU)
2015/830
Techspray G3 Flux Remover
SECTION 5: Firefighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without
suitable training. Move containers from fire area if this can be done without risk.
Use water spray to keep fire-exposed containers cool.
Hazardous combustion
products
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
halogenated compounds
carbonyl halides
Fire-fighters should wear appropriate protective equipment and self-contained
breathing apparatus (SCBA) with a full face-piece operated in positive pressure
mode. Clothing for fire-fighters (including helmets, protective boots and gloves)
conforming to European standard EN 469 will provide a basic level of protection for
chemical incidents.
Special protective
equipment for fire-fighters
:
:
5.3 Advice for firefighters
Special protective actions
for fire-fighters
:
6.2 Environmental
precautions
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Approach the release from upwind. Prevent entry into
sewers, water courses, basements or confined areas. Wash spillages into an
effluent treatment plant or proceed as follows. Contain and collect spillage with non-
combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
and place in container for disposal according to local regulations. Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilt product.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air). Water polluting material. May be harmful
to the environment if released in large quantities.
Large spill
:
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Dilute with water and mop up if water-soluble.
Alternatively, or if water-insoluble, absorb with an inert dry material and place in an
appropriate waste disposal container. Dispose of via a licensed waste disposal
contractor.
Small spill
:
6.3 Methods and material for containment and cleaning up
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency
personnel
:
For emergency responders
:
6.4 Reference to other
sections
See Section 1 for emergency contact information.
See Section 8 for information on appropriate personal protective equipment.
See Section 13 for additional waste treatment information.
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. In the case of aerosols being ruptured, care should be taken due to the
rapid escape of the pressurised contents and propellant. If a large number of
containers are ruptured, treat as a bulk material spillage according to the
instructions in the clean-up section. Do not touch or walk through spilt material.
Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid
breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator
when ventilation is inadequate. Put on appropriate personal protective equipment.
If specialised clothing is required to deal with the spillage, take note of any
information in Section 8 on suitable and unsuitable materials. See also the
information in "For non-emergency personnel".
:
:
Date of issue/Date of revision
:
5/11/2017
Date of previous issue
:
No previous validation
Version
:
1
5/14