An ideal mounting place for the thermo-hygro sensor would be the
outer wall beneath the extension of a roof, as this will protect the
sensor from direct sunlight and other extreme weather conditions.
To wall mount, use the 2 screws to affix the wall bracket to the
desired wall, plug in the thermo-hygro sensor to the bracket and
secure both parts by the use of the supplied screw and ensure that
the cables from the wind and rain sensors are correctly plugged in
otherwise data transmission errors could occur.
10. Resetting & factory settings:
As previously mentioned, in the event of a power reset to the sen-
sor (for example a change of batteries), the base station has to
synchronize to the sensor again otherwise no weather data will be
received. To do this, simply press and hold the PLUS(+) key for 2
seconds and a short beep will sound to synchronize the base sta-
tion to the sensor. When the units are synchronized, the data will
be received again and the base station will return to normal opera-
tion mode.
Do not reset the power of the base station otherwise all 175 sets of
recorded weather history data for transferring to the PC will be lost
(for full details of PC use, please see PC user manual in the en-
closed Heavy Weather CD-ROM).
However if you wish to make a full reset of the base station and
return to the original factory settings, simultaneously press and hold
the PRESSURE and WIND keys for about 5 seconds. The base
station will beep once and the entire LCD will light up for 5 seconds
and go back to the original factory settings. This process with clear
all previous user defined values and all weather history recordings.