Specifications
67
Mounting the Rain Sensor
For best results, the rain sensor should be securely mounted onto a
horizontal surface about 1 meter above the ground and in an open
area away from trees or other coverings where rainfall may be
reduced causing inaccurate readings.
When securing into place, check that rain excess will not collect
and store at the base of the unit but can flow out between the base
and the mounting surface (test by pouring clean water).
After mounting the rain sensor, connect the cable to the thermo-
hygro sensor at the corresponding socket so power supply can be
received and data be transmitted to the base station
The rain sensor is now operable. For testing purposes, very slowly
pour a small amount of clean water into the rain sensor funnel. The
water will act as rainfall and will be received and displayed at the
base station after about 2 minutes delay i.e. when the reading in-
terval is reached (to clear this testing data on the base station, refer
to the section “MIN/MAX Mode” below).
Mounting the thermo-hygro Sensor
Base portion
Funnel portion
Rain Cov-
er
Wall Bracket
Main Unit