Operation Manual

RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 9.3
9.2. CONFIGURATION OF SW PARAMETERS
The only configurable parameters are those for the machine lubrication. To change these values,
simultaneously press the when the 01 keys when the machine is in standby mode. The following
message will appear on the LCD:
P A S S W O R D = 0 0 0 0
T H E N E N T E R O R C L E A R
Type in the password 6144 and ENTER to confirm. The following message will appear on the
LCD:
L U B R I C A T I O N : W E A K = 1
M E D I U M = 2 S T R O N G = 3
To change the current configuration, press the number key (from 1 to 3) corresponding to the
desired choice. As soon as the number has been pressed, the new configuration becomes operative
and the machine reverts to the standby state
The procedure can be aborted at any time by pressing the “Clear” key.
The above procedure modifies the duration of the lubrication cycle expressed in seconds, and the
frequency of lubrication expressed in km covered by the machine, according to the table below:
LUBRICATION
Type Duration
Sec
Frequency
Km covered
Light 30 400
Medium 30 300
Heavy 15 100
If the machine is not equipped with the automatic lubrication system, the above
configuration parameters are ignored.
Downloaded from www.Manualslib.com manuals search engine