Operation Manual
RUNRACE : Service & Maintenance Manual - rev. 2.0
Page 9.1
9. MACHINE CONFIGURATION
9.1. HW MACHINE CONFIGURATION
The HW machine configuration is done via the 2 banks of 4 dip-switches at the rear of the CPU
board, proceeding as follows:
9.1.1. ENABLE USE OF EXTERNAL DEVICE
Using dip-switch No.1 of the right hand bank at the rear of the CPU board, select the type of
external connection:
Right hand bank
Dip-switch 1 Connection
ON Printer
OFF
None (HC1200)
External device
(HC1400)
9.1.2. LANGUAGE CONFIGURATION
Dip-switches No. 2, 3 and 4 of the right hand bank at the rear of the CPU board are used for
setting the language:
Right hand bank
Dip-switch
2 3 4
Language
OFF OFF OFF Italian (Kcal printouts)
OFF OFF ON English
OFF ON OFF German
OFF ON ON French
ON OFF OFF Dutch
ON ON ON Italian (VO2 printouts)
9.1.3. EXTERNAL DEVICE INTERFACE CONFIGURATION
On the HC1400 machine equipped with SW for ECG, the dip-switches of the left hand bank of the
CPU board are used for configuring the following parameters for external devices:
• Dip-switch No. 1: unit of measurement for heart rate:
Left hand bank
Dip-switch 1 Unit of measurement
ON Beats/minute
OFF % Max theoretical HR