Operation Manual

40
8. If more than one Power Monitor is detected, then a new ID of the newly detected Power Monitor will be
displayed in the LCD. Repeat procedure 6 and 7 for learning another channels. Maximum 5 channels
can be learnt.
9. Long press the LRN/SCAN key again to restart at procedure 3 if not all the desired Power Monitors are
learnt.
10. After learning reception is over a scanning will be started automatically.
IMPORTANT!
To update and receive any data from Power Monitor, user must press the LRN/SCAN key of
receiver every time to receive transmission of Power Monitor.
Note: When the receiver cannot receive data from power monitor over an hour, the “NEW DATA” (Figure 20)
will change to “OLD DATA” (Figure 21) displays on the LCD of the receiver. Also, the “OLD DATA” will be
displayed if no valid data is detected after pressing the “LRN/SCAN” key.
LOW BATTERY INDICATOR
Low battery indicator is displayed on the LCD when the batteries require changing. (Figure 22) It is performed:
after power up.
Figure 21
OLD
DATA
Figure 20
NEW
DATA