User's Manual
TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TDFM-136A Operating Instructions Page 2-25
TiL 09RE405
The commands available in this command level are:
L4-1 Set Default Record
This command allows the user to set up the default record that is used when a user selects
Create New/ Edit All (command 2-1). This allows those responsible for setting policy to determine
what parameters they wish to have as system defaults. Some of the parameters are subject to
restrictions set out in L4-9.
NOTE: If these values are set first, and the restrictions are set after, it is possible for the user to
end up using a parameter that you wish to restrict!
The Default Record editor works just like the Create New/ Edit All command (L2-1) except that it
takes you through all the possible squelch combinations so that each selection can be edited.
From the factory, the default channel parameters are as follows:
Table 2-6. The Channel Template Factory Defaults
Parameter Value
Basic Parameters
Scan List 1
Text Description “Desc “
Operating Mode w
Rx Parameters
Rx Frequency 141.0000
Rx Squelch Mode x
Rx Squelch TalkGroup Value $0001
Rx Squelch Tone Value 67.0
Rx Squelch Code Value 23
Rx NAC Value $293
Tx Parameters
Tx Frequency 141.0000
Tx Squelch Mode x
Tx Squelch TalkGroup Value $0001
Tx Squelch Tone Value 67.0
Tx Squelch Code Value 23
Tx NAC Value $293
Tx ID Call Value 0000001