User's Manual
TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TDFM-136A Operating Instructions Page 2-20
TiL 09RE405
L3-5.2 Setting the Reply Timer Range: 0-20s, Default: 3 seconds
The next screen allows the user to set the scan Reply time. This is the time that the radio will
monitor a channel on which RF was received, after all activity on the channel has ended (Rx or
Tx). If there is further receive or transmit activity on the channel, the timer will reset, and start
again once the activity has ended. When the timer times-out the unit will resume scan. If set to
zero (0), the unit will resume scan immediately upon end of channel activity.
3 - 5 E d i t S c a n P a r a m e t e r s
R e p l y T i m e r : 0 3
FIGURE 2-24 User Screen to Set the Scan Reply Timer Value
The user can set the Scan Reply Timer value as follows:
to
to decimal mode: enter number, cursor automatically advances
advance to next screen
abandon the entry and exit
L3-5.3 Setting the Monitor Timer Range: 1-90s, Default: 10 seconds
The next screen allows the user to set the scan Monitor time, this is the time that the radio will
monitor a channel on which RF was received, before resuming scanning. Once the timer expires,
the unit will break and resume scan, if the value is set to zero (0) then the unit will monitor the
signal as long as it is received. The edit screen is as follows:
3 - 5 E d i t S c a n P a r a m e t e r s
M o n i t o r T i m e r : 1 0
FIGURE 2-25 User Screen to Set the Scan Monitor Timer Value
The user can set the Scan Monitor Timer value as follows:
to
to decimal mode: enter number, cursor automatically advances
advance to next screen
abandon the entry and exit