User's Manual
Table Of Contents
- Front Cover
- Foreword
- Table of Contents
- Foreword ii
- List of Figures vii
- List of Tables xi
- Commercial Warranty xiii
- Model Numbering, Charts, and Specifications xvii
- Chapter 1 Introduction 1-1
- Chapter 2 Radio Power 2-1
- Chapter 3 Theory of Operation 3-1
- Chapter 4 Troubleshooting Procedures 4-1
- Chapter 5 Troubleshooting Charts 5-1
- Chapter 6 Troubleshooting Waveforms 6-1
- Chapter 7 Troubleshooting Tables 7-1
- Chapter 8 Schematics, Board Overlays, and Parts Lists 8-1
- Appendix A Replacement Parts Ordering A-1
- Glossary Glossary-1
- Index Index-1
- List of Figures
- List of Tables
- Related Publications
- Commercial Warranty
- Model Numbering, Charts, and Specifications
- Portable Radio Model Numbering System
- ASTRO XTS5000 VHF Model Chart
- ASTRO XTS5000R (Ruggedized) VHF Model Chart
- ASTRO XTS5000 UHF Range 1 Model Chart
- ASTRO XTS5000R (Ruggedized) UHF Range 1 Model Chart
- ASTRO XTS5000 700–800MHz Model Chart
- ASTRO XTS5000R (Ruggedized) 700–800MHz Model Chart
- Specifications for VHF Radios
- Specifications for UHF Range 1 Radios
- Specifications for 700–800 MHz Radios
- Chapter 1 Introduction
- Chapter 2 Radio Power
- Chapter 4 Troubleshooting Procedures
- Chapter 5 Troubleshooting Charts
- 5.1 List of Troubleshooting Charts
- 5.2 Main Troubleshooting Flowchart
- 5.3 Power-Up Failure
- 5.4 DC Supply Failure
- 5.5 Display Failure (NNTN4563, NNTN4819, & NNTN4717 VOCON Kits)
- 5.6 Display Failure (NTN9564)
- 5.7 Volume Set Error
- 5.8 Channel/Zone Select Error
- 5.9 Button Test
- 5.10 Top/Side Button Test
- 5.11 VCO TX/RX Unlock
- 5.12 VOCON TX Audio
- 5.13 VOCON RX Audio
- 5.14 RX RF
- 5.15 TX RF (VHF)
- 5.16 TX RF (UHF R1/700-800MHz)
- 5.17 Keyload Failure
- 5.18 Secure Hardware Failure
- Chapter 6 Troubleshooting Waveforms
- Chapter 7 Troubleshooting Tables
- Appendix A Replacement Parts Ordering
- Glossary
- Index
- Back Cover
October 14, 2003 6881094C31-C
5-14 Troubleshooting Charts: Volume Set Error
5.7 Volume Set Error
MAEPF-27401-A
No
No
No
Ye s
Ye s
Ye s
Volume
Set Error
Using a voltmeter,
measure voltage at
U507 pin 1, when volume
knob is all the way on.
The value should be V2*
Voltage
Functional?
Replace
U501
Verify connections
and control top/PTT
flex connections
Volume
check OK?
Refer to
VOCON RX
Audio flowchart
Verify operation
of volume knob
using Button Test
flowchart
Replace
U507
Volume
pot OK?
Replace Front
Cover Housing
Assembly
This chart relates to a failure in the volume
set knob. Basic failure modes are as follows:
1) Failure in control top/PTT flex circuit
2) Bad connection
3) Defective volume control potentiometer
4) Defective A/D port in GCAP II
5) Problem in receive audio circuit
Synopsis
Measure voltage from
R526 to GND while
moving volume knob
from min to max. Max
volume is 2.50V
* per Standard Bias Table