User's Manual

Table Of Contents
October 14, 2003 6881094C31-C
5-16 Troubleshooting Charts: Button Test
5.9 Button Test
MAEPF-27399-O
End
Keys
correct?
Check signal
path integrity of
button in question
Button Test
Place radio in Test Mode.
Press Top Side Button
(Monitor) so display reads
CH TEST. This places the
radio in button test mode.
Then, press the orange
(Emergency) Top Button
to verify codes displayed
as shown in the Button
Table at right
No
Ye s
This chart relates to a failure in the button functions
Basic Failure modes are as follows:
1) Failure in control top/PTT or keypad flex assembly
2) Bad Connection
3) Defective Switches or pads
4) Defective A/D port in GCAP II
Synopsis
Button Table
Button
PTT
Top Button (Emergency)
Side Button 1 (Monitor)
Side Button 2
Side Button 3
Channel Select (Frequency)
Volume Control Knob
Zone Select
Code
1/ 0-1
3/ 0-1
96/ 0-1
97/ 0-1
98/ 0-1
4/ 0-15
0/ 0-244
65/ 0-2
128/1
130/1
135/1
136/1
Home Alpha
129/1
134/1
132/1
131/1
133/1
53/1
5JKL
52/1
4GHI
54/1
6MNO
50/1
2ABC
49/1
1
51/1
3DEF
48/1
0
58/1
*
59/1
#
56/1
8TUV
55/1
7PRS
57/1
9XYZ
Navigation
Button