Installation Instructions
 16 
EN 
MONT
_
TechniLAN
_
4
_
4
_
aktiv
_
DE
_
EN.doc 04.09.2012 09:51 Seite 16
Power Consumption 
(without sockets and 
distribution technology) 
max. 400 mA 
type 250 mA 
Dimensions: L x B x H (mm), 
Weight 
121 x 114 x 33, 240 g 
7  Error Search Assistance 
Error Possible Causes  Help 
The data rate is too low. 
•  Inputs and outputs of the 
TechniLAN 4/4 active have 
been switched. 
•  The dampening between the 
TechniLAN 4/4 aktiv and the 
socket is too effective 
•  Check whether or not the device is 
correctly connected with the multi-
switch and/or the LNB. 
•  Check the cabling. 
The green power LED 
of a participant socket 
does not light up. 
A short circuit has occurred 
between the participant socket and 
the TechniLAN 4/4 aktiv. 
•  Check the cabling. 
The power LED of the 
TechniLAN does not 
light up 
The wall power supply switched off 
due to overloading 
•  Check the cabling for short circuits. 
•  Connect a separate wall power 
supply with the multi-switch. 
The yellow traffic LED of 
the participant socket 
does not light up. 
Up to now, no successful LAN 
connection could be established via 
the coaxial cable 
•  Wait a few seconds, establishing a 
connection might take a few minutes. 
•  Check the cabling. 
Connected receivers 
signal short circuits 
within the LNB cable for 
specific programs 
The receiver is not capable of 
supplying the TechniLAN socket as 
well as the distribution system with 
enough power, especially when 
selecting programs from the 
horizontal polarization (18 V). 
•  Connect a separate wall power 
supply with the multi-switch. 
Your device is CE approved and meets all necessary EU standards.
Subject to changes and printing errors. Status 8/12 
Reproduction and copies are only allowed with the consent of the publisher. 