315-4PN33

Device overview
Module ... Slot ... Type ...
PLC... 2 CPU ...
... ... ...
3
DI... 4 DI...
DO... 5 DO...
DIO... 6 DIO...
AI... 7 AI...
AO... 8 AO...
CP 343-1
9 CP 343-1
CP 342-5
10 CP 342-5
Thus, the VIPA components can be displayed, you have to
deactivate the "Filter" of the hardware catalog.
1. Switch in the Project area to Network view.
2. Connect the slave system "VIPA_SPEEDbus". After installing
the SPEEDBUS.GSD this may be found in the hardware catalog
at: Other field devices > PROFIBUS DP > I/O > VIPA GmbH >
VIPA_SPEEDbus.
3. For the slave system set the PROFIBUS address 100.
Connect
VIPA_SPEEDbus
VIPA System 300S Configuration with TIA Portal
TIA Portal - Setting VIPA specific CPU parameters
HB140 | CPU | 315-4PN33 | GB | 14-43 157