315-4PN33

n If you connect communication devices to a switch with more tan 2
PROFINET ports, you automatically create a star network top-
ology.
n If an individual PROFINET device fails, this does not automatically
lead to failure of the entire network, in contrast to other structures.
It is only if a switch fails that part of the communication network
will fail as well.
In order to increase the availability of a network the both open ends of
a linear bus topology may be connected by a switch. By configuring
the switch as redundancy manager on a break in the network it
ensures that the data is redirected over an intact network connection.
If you interconnect several star structures, you obtain a tree network
topology.
8.3 PROFINET system limits
D Devices per ms
n Number of devices
A Refresh time device
The PROFINET IO controller has the following system limits
Devices per ms Max. number of
devices
Max. number of
configurable con-
nections
8 32 0
7 32 2
6 64 4
5 96 6
4 128 8
3 128 12
2 128 16
Star
Ring
Tree
Example network
Devices per ms
VIPA System 300S Deployment Ethernet communication - PROFINET
PROFINET system limits