Instructions

Indoor Monitor View the Camera
In standby mode, press monitor key on indoor monitor to view live bild of
outdoor unit. In this mode, the blue LED lights up. If outdoor unit receives signal in
5 seconds, then it connects to indoor monitor, indoor machine turns into normal
monitor mode and shows image and speaks voice of outside. There is no voice
speaking for outdoor unit. If outdoor unit doesn’t receive signal in 5 seconds, then
it shows “User not online” and exits monitor calling mode automatically and turns
into standby mode.
Two sets of outdoor units (Code connected successfully):
Press monitor key on indoor monitor to turn into monitor selection menu
press / key to choose code of outdoor units press OK to turn into monitoring
call mode, blue LED lights up (During selection, press “Exit” to turn into standby
mode ).
Intercom: in monitor mode, red LED lights up, there is voice speaking for
indoor monitor but not for outdoor unit press monitor key to turn into
both-way communication, blue LED shuts down press monitor key
again to turn back to one way voice monitor mode. (One or both-way voice could
be changed over repeatedly). Intercom time is 90 seconds and shall be timed
again after changing over.
Unlock: in OK on-state mode press unlock key after successful
unlocking, it shows unlock icon.
Take a photo: in monitor mode press photo taking key one press
one photo, the photos will be stored in MicroSD card.
Video Recording: in monitor mode press video taking key start
taking video press video taking key again to stop, the videos will be
stored in MicroSD card.
End: in monitor mode press OK key end monitor and turn back to
standby mode.
NOTE: in monitor mode, red LED lights up, in intercom mode, red LED shuts
down.
Indoor Monitor CALL Indoor Monitor (Intercom)
(Only can realize when there are 2 and more indoor monitors.)
In standby mode, if there are only two indoor monitors in system, press OK to
call another indoor monitor.
In standby mode, if there are three indoor monitors in system, press to call
small code indoor monitor. Ppress to call large code indoor monitor.
If the CALLED indoor monitor does not receive the signal in 4 seconds, the
CALL monitor shows “User not online”, it turns back to standby mode with a
sound of “Beep”.
If the CALLED indoor monitor receives the signal, two monitors play music, red
LED lights up.
If the CALLED indoor monitor doesn’t reply, the monitors turn into standby
mode after 30 seconds.
If the CALLED indoor monitor replies by pressing OK, music stops, red LED
shuts down, blue LED lights up to both of the monitors, and both monitors turn
into intercom mode, communication time is max. 90 seconds.
The CALL indoor monitor has initiative hang up function.
During communication, if any end in the communication presses OK, then both
two ends hang up with a sound of “Beep” and turn to standby mode.