User manual

57
activation stays such as the buzzer, tour, PTZ activation, snapshot, channel record. The
stay time here does not include the latch time. During the alarm process, the alarm signal
can begin an anti-dither time if system detects the local alarm again. The screen prompt,
alarm upload, email and etc will not be activated. For example, if you set the anti-dither
time as 10 second, you can see the each activation may last 10s if the local alarm is
activated. During the process, if system detects another local alarm signal at the fifth
second, the buzzer, tour, PTZ activation, snapshot, record channel will begin another 10s
while the screen prompt, alarm upload, email will not be activated again. After 10s, if
system detects another alarm signal, it can generate an alarm since the anti-dither time is
out.
Period: Click set button, you can see an interface is shown as in Figure 4-78. Here you
can set motion detect period. System only enables motion detect operation in the
specified periods. It is not for video loss or the tampering. There are two ways for you to
set periods. Note system only supports 6 periods in one day.
In Figure 4-78, Select icon of several dates, all checked items can be edited
together. Now the icon is shown as . Click to delete a record type from one
period.
Click button after one date or a holiday, you can see the schedule interface. There
are four record types: regular, motion detection (MD), Alarm, MD & alarm.
Alarm output: when an alarm occurs, system enables peripheral alarm devices.
Latch: when motion detection complete, system auto delays detecting for a specified
time. The value ranges from 1-300(Unit: second)
Show message: System can pop up a message to alarm you in the local host screen if
you enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
centre) if you enabled current function.
Send email: System can send out email to alert you when an alarm occurs.
Record channel: System auto activates motion detection channel(s) to record once an
alarm occurs. Make sure you have set MD record in Schedule interface(Main
Menu->Setting->Schedule) and schedule record in manual record interface(Main
Menu->Advanced->Manual Record)
PTZ activation: Here you can set PTZ movement when an alarm occurs. Such as go to
preset, tour &pattern when there is an alarm. Click ―select‖ button, you can see an
interface is shown as in Figure 4-77.
Record Delay: System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
Tour: Here you can enable tour function when alarm occurs. System one-window tour.
Snapshot: You can enable this function to snapshoot image when a motion detect alarm
occurs.
Video matrix (optional): Check the box here to enable this function. When an alarm