User manual
141
Figure5‐59
Refer to the following sheet for detailed information.
Parameter Function
Enable You need to check the box to enable this function.
Select a channel from the dropdown list.
Period This function becomes activated in the specified periods.
There are six periods in one day. Draw a circle to enable
corresponding period.
Select date. If you do not select, current setup applies to
today only. You can select all week column to apply to the
whole week.
Click OK button, system goes back to local alarm
interface, click save button to exit.
Anti-dither
System only memorizes one event during the anti-dither
period. The value ranges from 5s to 600s.
Sensor type
There are two options: NO/NC.
Record channel System auto activates motion detection channel(s) to
record once an alarm occurs. Note you need to set alarm
record period and go to Storage-> Schedule to set current
channel as schedule record.
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Alarm out Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.
Latch
System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
Show message System can pop up a message to alarm you in the local
host screen if you enabled this function.
Buzzer Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
Alarm upload System can upload the alarm signal to the centre
(Including alarm centre).