In Figure 4-93, Select icon of several dates, all checked items can be edited
together. Now the icon is shown as
. Click to delete a record type from one
period.
In
Figure 4-93. Click button after one date or a holiday, you can see an interface
shown as in Figure 4-94. There are four record types: regular, motion detection (MD),
Alarm, MD & alarm.
Anti-dither: Here you can set anti-dither time. Here you can set anti-dither time. The value
ranges from 5 to 600s. The anti-dither time refers to the alarm signal lasts time. It can be
seem as the alarm signal activation stays such as the buzzer, tour, PTZ activation, snapshot,
channel record. The stay time here does not include the latch time. During the alarm process,
the alarm signal can begin an anti-dither time if system detects the local alarm again. The
screen prompt, alarm upload, email and etc will not be activated. For example, if you set the
anti-dither time as 10 second, you can see the each activation may last 10s if the local alarm
is activated. During the process, if system detects another local alarm signal at the fifth
second, the buzzer, tour, PTZ activation, snapshot, record channel will begin another 10s
while the screen prompt, alarm upload, email will not be activated again. After 10s, if system
detects another alarm signal, it can generate an alarm since the anti-dither time is out.
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
centre) if you enabled current function.
Send email: System can send out email to alert you when alarm occurs.
Record channel: you can select proper channel to record alarm video (Multiple choices). At
the same time you need to set alarm record in schedule interface (Main Menu->Setting-
>Schedule) and select schedule record in manual record interface (Main Menu->Advance-
>Manual Record).
Latch: Here is for you to set proper delay duration. Value ranges from 10 to 300 seconds.
System automatically delays specified seconds in turning off alarm and activated output after
external alarm cancelled.
Tour: Here you can enable tour function when alarm occurs. System supports 1/8-window
tour. Note the tour setup here has higher priority than the tour setup you set in the Display
interface. Once there two tours are both enabled, system can enable the alarm tour as you
set here when an alarm occurred. If there is no alarm, system implements the tour setup in
the Display interface.
Snapshot: System can snapshoot corresponding channel when an alarm occurs. Note the
activation snapshot has the higher priority than schedule snapshot. If you have enabled
these two types at the same time, system can activate the activation snapshot when alarm
occurs, and otherwise system just operates the schedule snapshot.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Note, network alarm means the alarm signal from the TCP/IP. You can use NET SDK to
activate network alarm. Comparing with the local alarm, there is no type, anti-dither, alarm
upload function.
Highlight icon
to select the corresponding function. After setting all the setups click save
button, system goes back to the previous menu.