detection zone. After you completed the setup, click ENTER button to exit current setup. Do
remember click save button to save current setup. If you click ESC button to exit the region
setup interface system will not save your zone setup.
Sensitivity: System supports 6 levels. The sixth level has the highest sensitivity.
Anti-dither: Here you can set anti-dither time. The value ranges from 5 to 600s. The anti-
dither time refers to the alarm signal lasts time. It can be seem as the alarm signal activation
stays such as the buzzer, tour, PTZ activation, snapshot, channel record. The stay time here
does not include the latch time. During the alarm process, the alarm signal can begin an anti-
dither time if system detects the local alarm again. The screen prompt, alarm upload, email
and etc will not be activated. For example, if you set the anti-dither time as 10 second, you
can see the each activation may last 10s if the local alarm is activated. During the process, if
system detects another local alarm signal at the fifth second, the buzzer, tour, PTZ
activation, snapshot, record channel will begin another 10s while the screen prompt, alarm
upload, email will not be activated again. After 10s, if system detects another alarm signal, it
can generate an alarm since the anti-dither time is out.
Period: Click set button, you can see an interface is shown as in Figure 4-84. Here you can
set motion detect period. System only enables motion detect operation in the specified
periods. It is not for video loss or the tampering. There are two ways for you to set periods.
Note system only supports 6 periods in one day.
In Figure 4-84, Select icon
of several dates, all checked items can be edited together.
Now the icon is shown as . Click to delete a record type from one period.
In Figure 4-84. Click button after one date or a holiday, you can see an interface shown
as in Figure 4-85. There are four record types: regular, motion detection (MD), Alarm, MD &
alarm.
Alarm output: when an alarm occurs, system enables peripheral alarm devices.
Latch: when motion detection complete, system auto delays detecting for a specified time.
The value ranges from 1-300(Unit: second)
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm
centre) if you enabled current function.
Send email: System can send out email to alert you when an alarm occurs.
Record channel: System auto activates motion detection channel(s) to record once an alarm
occurs. Make sure you have set MD record in Schedule interface(Main Menu->Setting-
>Schedule) and schedule record in manual record interface(Main Menu->Advanced->Manual
Record)
PTZ activation: Here you can set PTZ movement when an alarm occurs. Such as go to
preset, tour & pattern when there is an alarm. Click select button, you can see an interface
is shown as in Figure 4-83
X.
Record Delay: System can delay the record for specified time after alarm ended. The value
ranges from 10s to 300s.
Tour: Here you can enable tour function when alarm occurs. System one-window tour.
Snapshot: You can enable this function to snapshoot image when a motion detect alarm
occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Test: Click it to test current motion detect setup (do not need to save). Click Select button
after Region, you can set motion detect area.
Highlight icon to select the corresponding function. After all the setups click save button,
system goes back to the previous menu.