Refer to the following sheet for detailed information.
Parameter Function
Channel
Select speed dome connected channel.
PTZ type
There are two options: local/remote.
Control mode
You can select control mode from the dropdown list. There are two options:
Serial/HDCVI. For HDCVI series product, select HDCVI. The control signal
is sent to the PTZ via the coaxial cable. For the serial mode, the control
signal is sent to the PTZ via the RS485 port.
Protocol
Select corresponding protocol from the dropdown list.
Address
Set corresponding dome address. Default value is 1. Note your setup
here shall comply with your dome address; otherwise you can not
control the speed dome.
Baud Rate
Select the dome baud rate. Default setup is 9600.
Data Bit Default setup is 8. set according to the speed dome dial switch setup.
Stop bit
Default setup is 1. Set according to the speed dome dial switch setup.
Parity Default setup is none. Set according to the speed dome dial switch setup.
5.8.5.4 ATM / POS
The ATM/POS function is for financial areas. It includes Sniffer, information analysis and title
overlay function. The Sniffer mode is network. The network type interface is shown as below. See
Figure 5-75. Here we take the ATM/POS protocol to continue. There are two types: with or
without the protocol according to client’s requirements.
With the protocol: For ATM/POS with the protocol, you just need to set the source IP,
destination IP (sometimes you need to input corresponding port number).
Figure5‐75