User manual
144
Figure5‐59
Refer to the following sheet for detailed information.
Parameter Function
Enable You need to check the box to enable this function.
Select a channel from the dropdown list.
Period This function becomes activated in the specified periods.
There are six periods in one day. Draw a circle to enable corresponding
period.
Select date. If you do not select, current setup applies to today only. You
can select all week column to apply to the whole week.
Click OK button, system goes back to local alarm interface, click save
button to exit.
Anti-dither
System only memorizes one event during the anti-dither period. The
value ranges from 5s to 600s.
Sensor type
There are two options: NO/NC.
Record channel System auto activates motion detection channel(s) to record once an
alarm occurs. Note you need to set alarm record period and go to
Storage-> Schedule to set current channel as schedule record.
Record Delay
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
Alarm out Enable alarm activation function. You need to select alarm output port so
that system can activate corresponding alarm device when an alarm
occurs.
Latch
System can delay the alarm output for specified time after an alarm
ended. The value ranges from 1s to 300s.
Show message System can pop up a message to alarm you in the local host screen if
you enabled this function.
Buzzer Check the box here to enable this function. The buzzer beeps when an
alarm occurs.
Alarm upload System can upload the alarm signal to the centre (Including alarm
centre).
Send Email If you enabled this function, System can send out an email to alert you
when an alarm occurs.