User Manual

Technalogix Ltd.
VIII-10
POWER - Tactile button to turn carriers on and off. To turn off, must be depressed for at least 2
seconds. Tied internally through DB9 connectors to all other POWER buttons.
NAVIGATE - Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver.
SELECT- Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver
RESET - Tactile button to reset microcontroller in control board. Also clears existing faults.
Individual control board with reset comes back on with soft start feature.
PA1 and PA2 RF IN RF input from the output of each power amplifier. N connector, 50 .
RF OUT 1,000-watt RF output to be connected with inline wattmeter and then to antenna. N
connector, 50 .
PA CTRL Control signals communicating from the combiner enclosure to the power amplifier
enclosures. Connects with the PA 1 and PA 2 CTRL connector on the power amplifier.
DB9 connector (see Amplifier Monitoring section for pinout description).
REMOTE PORT - pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample
AC IN AC input to switching power supply. Switching power supply draws a
maximum of 2 A
AC
at 110 V
AC
.