User Manual

Technalogix Ltd.
VIII-
8
POWER - Tactile button to turn carriers on and off. To turn off, must be depressed for at least
2 seconds. Tied internally through DB9 connectors to all other ON/OFF buttons.
NAVIGATE - Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver.
SELECT- Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver.
RESET - Momentary pushbutton to reset microcontroller in control board. Also clears existing
faults. Individual control board with reset comes back on with soft start feature.
RF IN RF input from the output of the RF splitter. BNC connector, 50 .
RF OUT 500-watt RF output to be combined with the other 500-watt output. Connects to RF IN
PA 1 or 2 on combiner unit. N connector, 50 .
PA CTRL Control signals communicating with the combiner enclosure. Connects with the PA 1
and PA 2 CTRL connector on the combiner. DB9 connector (see Amplifier Monitoring
section for pinout description).
REMOTE PORT - pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample
AC IN AC input to switching power supply. Switching power supply draws a
maximum of 8 A
AC
at 220 V
AC