Operation Manual
Table Of Contents
- Antenna and Tower Recommendations (if applicable)
- The fans internal to the enclosures help cool the components. The specific fan voltages and part numbers are listed in the Block Diagram included with the Quickstart package.
- Unpacking and Inspection
- FM Amplifier Pallets
- The following is a summary of the typical FM amplifier pallets used in Technalogix power amplifiers and transmitters out of the many pallets that have been designed for production or custom applications. The exact bias and drain currents of your syste...
- PB1A-50-1000-1042H
1
Safeguards
2
Terms and
Warranty
3
Principle of
Operation
4
Installation
5
Operation
6
Control System
7
RF Components
7
RF Components
9
Maintenance
10
Troubleshooting
1,500W LPF, with coupler
Frequency Range
86 – 110 MHz
Input Power (max)
1,500 W continuous
Order
9
th
order Chebyshev
Insertion Loss (max)
< 0.2 dB
Insertion Loss (typ)
< 0.15 dB
Return Loss (max)
> 25 dB
Return Loss (typ)
> 30 dB
Rejection at 176 MHz
> -47 dB
Directivity (min)
20 dB
1,500W LPF, with -50dB coupler
Frequency Range
86 – 110 MHz
Input Power (max)
1,500 W continuous
Order
9
th
order Chebyshev
Insertion Loss (max)
< 0.12 dB
Insertion Loss (typ)
< 0.1 dB
Return Loss (max)
> 28 dB
Return Loss (typ)
> 33 dB
Rejection at 176 MHz
> -47 dB
Directivity (min)
20 dB
2,000W LPF, no coupler
Frequency Range
86 – 110 MHz
Input Power (max)
2,000 W continuous
Order
9
th
order Chebyshev
Insertion Loss (max)
< 0.12 dB
Insertion Loss (typ)
< 0.1 dB
Return Loss (max)
> 23 dB
Return Loss (typ)
> 25 dB
Rejection at 176 MHz
> -45 dB
3,600W LPF, with coupler
Frequency Range
MHz
Input Power (max)
3,600 W continuous
Order
9
th
order Chebyshev
Insertion Loss (max)
< dB
Insertion Loss (typ)
< dB
Return Loss (max)
> dB
Return Loss (typ)
> dB
Rejection at 176 MHz
> dB
Directivity (min)
> - dB