This screen allows the user to change settings to the RF levels, including the
Forward RF level (the reflected (VSWR) trip point is changed from the Settings
screen. From the RF Levels screen, the user can also toggle between AGC and
Manual mode. The RF Levels Screen is displayed below:
To adjust Forward RF Level:
Press the up or down arrows (in either 1 or 10% increments or decrements) until
the desired Forward RF level is reached. If the adjusted level exceeds 110%, the
protection will kick in and the system will fold back the RF power to a safe level.
There may be a residual amount of Forward RF power even at 0% setting, but it
should be insignificant.