User's Manual

1
Safeguards
2
Terms and
Warranty
3
Principle of
Operation
4
Installation
5
Operation
6
Control System
7
RF Components
8
Power Supply
9
Maintenance
10
Troubleshooting
1,500W LPF, with coupler
Frequency Range 86 – 110 MHz
Input Power (max) 1,500 W continuous
Order 9
th
order Chebyshev
Insertion Loss (max) < 0.2 dB
Insertion Loss (typ) < 0.15 dB
Return Loss (max) > 25 dB
Return Loss (typ) > 30 dB
Rejection at 176 MHz > -47 dB
Directivity (min) 20 dB
1,500W LPF, with -50dB coupler
Frequency Range 86 – 110 MHz
Input Power (max) 1,500 W continuous
Order 9
th
order Chebyshev
Insertion Loss (max) < 0.12 dB
Insertion Loss (typ) < 0.1 dB
Return Loss (max) > 28 dB
Return Loss (typ) > 33 dB
Rejection at 176 MHz > -47 dB
Directivity (min) 20 dB
2,000W LPF, no coupler
Frequency Range 86 – 110 MHz
Input Power (max) 2,000 W continuous
Order 9
th
order Chebyshev
Insertion Loss (max) < 0.12 dB
Insertion Loss (typ) < 0.1 dB
Return Loss (max) > 23 dB
Return Loss (typ) > 25 dB
Rejection at 176 MHz > -45 dB
3,600W LPF, with coupler
Frequency Range MHz
Input Power (max) 3,600 W continuous
Order 9
th
order Chebyshev
Insertion Loss (max) < dB
Insertion Loss (typ) < dB
Return Loss (max) > dB
Return Loss (typ) > dB
Rejection at 176 MHz > dB
Directivity (min) > - dB