User's Manual

Technalogix Ltd.
VIII-8
POWER - Tactile button to turn carriers on and off.
NAVIGATE - Tactile button to move between menu items, or to refresh the screen after it
has timed out.
SELECT- Tactile button to select menu item, or to refresh the screen after it has timed
out.
RESET - Tactile button to reset microcontroller in control board. Also clears existing
faults. The amplifier will come back on with the soft start feature.
RF IN RF input from modulator or processor. BNC connector, 50 ohm.
RF OUT 100-watt RF output. Connects to inline wattmeter (not supplied) and antenna. N
connector, 50 ohm.
REMOTE PORT - Port to monitor and control the amplifier externally. See “ Monitor and
Control” section for pin-out.
AC IN AC input to switching power supply.
AC BREAKER Resettable circuit breaker is used to protect against inrush currents and
high current draw from switching power supply. The thermal circuit breaker
is a single pole configuration.
AC ON/OFF - AC rocker switch (SPST) to supply AC to the AC-DC switching power supply