User's Manual

Technalogix Ltd.
VIII-8
POWER - Tactile button to turn carriers on and off. To turn off, must be depressed for
at least 2 seconds. Tied internally through DB9 connectors to all other
POWER buttons.
NAVIGATE - Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
SELECT- Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
RESET - Tactile button to reset microcontroller in control board. Also clears existing
faults. Individual control board with reset comes back on with soft start feature.
AC IN AC input to switching power supply. Switching power supply draws a maximum
of 30 A
AC
at 220 V
AC
.
AC BREAKER 30-ampere resettable circuit breaker is used to protect against inrush
currents and high current draw from switching power supply. The thermal
circuit breaker is a single pole configuration.
PA PSU - DC supply outputs to each power amplifier. DC cabling is identical and can
be hooked up to PA2.
AC ON/OFF - AC rocker swith (SPST) to supply AC to the AC-DC switching power supply.