User's Manual

Technalogix Ltd.
VIII-10
POWER - Tactile button to turn carriers on and off. To turn off, must be depressed for
at least 2 seconds. Tied internally through DB9 connectors to all other
POWER buttons.
NAVIGATE - Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
SELECT- Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
RESET - Tactile button to reset microcontroller in control board. Also clears existing
faults. Individual control board with reset comes back on with soft start feature.
AC IN AC input to switching power supply (31 V
DC
supply for control system and
power supplies). Use supplied NEMA to terminal block connector cable.
DC OUT - DC power supply output to power amplifier enclosure
AC ON/OFF - AC rocker switch (SPST) to supply AC to the AC-DC Switching power
supply.