User's Manual

Technalogix Ltd.
VIII-8
POWER - Tactile button to turn carriers on and off. To turn off, must be depressed for
at least 2 seconds. Tied internally through DB9 connectors to all other
POWER buttons.
NAVIGATE - Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
SELECT- Tactile button to refresh screen after two minute screen saver times out. All
monitoring and protection continues during screen saver.
RESET - Tactile button to reset microcontroller in control board. Also clears existing
faults. Individual control board with reset comes back on with soft start feature.
RF IN RF input from modulator or processor. BNC connector, 50 ohm.
RF OUT 500-watt RF output. Connects to RF IN on filter enclosure. N connector, 50
ohm.
DC IN DC input from power supply enclosure. Polarized to avoid improper hook up.
REMOTE PORT - pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample (28Vdc nominal)