User's Manual

P-379 Processor
18
5. Select the desired output channel. Unless otherwise specified, the unit is factory
set for cable standard channel frequencies and the microprocessor automatically
selects the proper FCC offset for the output channels, requiring no calculations or
adjustments.
NOTE: For HRC output channels, see the section in this manual entitled
HRC Output Frequency Set.
During output-channel tuning, the FREQUENCY LOCK LED on the front panel
display may also blink during input-channel tuning. This is because, when the
unit is being tuned, an RF-output muting circuit is enabled to ensure that moving
RF carriers do not interfere with any existing channels on the cable system.
6. Connect a spectrum analyzer (recommended) or a field strength meter to the F-
connector marked “RF OUTPUT” on the rear panel of the P-379 agile processor.
If the unit is already connected to another device, disconnect that device from the
unit.
7. using the front panel control marked “OUTPUT LEVEL,” adjust the RF output of
the unit. The recommended output level is between +55dBmV and +60dBmV
(+115dBuV and +120dBuV).
Setting the RF output level below +55dBmV may adversely affect the parameters
of the modulating signal; setting the RF output level above +60dBmV will
adversely affect the quality of performance of the P-379. Ensure that the RF
output level is checked each time an output channel is selected, particularly
when the selected channel is a return or “T” channel or when the channel
selected is in a different band from the previous channel.
NOTE: Ensure that you do not overdrive the power amplifier. Please see
the power amplifier manual for recommended levels.