User Manual
Dell
PowerEdge R710 Technical Guide 20
ReadyRails Static Rails
ReadyRails
TM
Static Rails for 4-post and 2-post racks support the following:
• Toolless installation in 19” EIA-310-E compliant square or unthreaded round hole 4-post racks including
all generations of Dell racks
• Tooled installation in 19” EIA-310-E compliant threaded hole 4-post and 2-post racks
See section 14 for more details.
Fans
Five hot-swappable fans are mounted in a fan gantry that is located in the chassis between the hard drive bay
and the processors. See Figure 7. Each fan has a blind mate 2x2 connector that plugs directly into the planar.
There is an additional fan integrated in each power supply to cool the power supply subsystem and also provide
additional cooling for the whole system. Single processor configurations have four fans populated.
Fan Gantry Figure 7.
The Embedded Server Management logic in the system monitors the speed of the fans. A fan failure or over-
temperature in the system results in a notification by iDRAC6. All system fans are pulse-width modulated fans.
Redundant cooling is supported.
LCD Control Panel
The LCD control panel is located on the front of the system chassis to provide user access to switches, display,
and I/O interfaces. See Figure 8. The control panel includes the following features:
• ACPI-compliant power button with an integrated green power LED (controlled by iDRAC6)
• 128x20 pixel LCD with controls:
o Two navigation buttons
o Select button
o System ID button
• Non-maskable Interrupt (NMI) button (recessed)
• Ambient temperature sensor