Installation Manual
Configuring SMTP Email Server Address Settings Using iDRAC7 Web Interface
To configure the SMTP server address:
1. In iDRAC7 Web interface, go to Overview → Server → Alerts → SNMP and E-mail Settings.
2. Enter the valid IP address or fully qualified domain name (FQDN) of the SMTP server to be used in the configuration.
3. Select the Enable Authentication option and then provide the user name and password (of a user who has access
to SMTP server).
4. Enter the SMTP port number.
For more information about the fields, see the
iDRAC7 Online Help
.
5. Click Apply.
The SMTP settings are configured.
Configuring SMTP Email Server Address Settings Using RACADM
To configure the SMTP email server, use one of the following:
• Using set command:
racadm set iDRAC.RemoteHosts.SMTPServerIPAddress <SMTP E-mail Server IP
Address>
• Using config command:
racadm config -g cfgRemoteHosts -o cfgRhostsSmtpServerIpAddr <SMTP E-mail
Server IP Address>
Configuring WS Eventing
The WS Eventing protocol is used for a client service (subscriber) to register interest (subscription) with a server (event
source) for receiving messages containing the server events (notifications or event messages). Clients interested in
receiving the WS Eventing messages can subscribe with iDRAC and receive Lifecycle Controller job related events.
The steps required to configure WS eventing feature to receive WS Eventing messages for changes related to Lifecycle
Controller jobs are described in the Web service Eventing Support for iDRAC7 1.30.30 specification document. In addition
to this specification, see the DSP0226 (DMTF WS Management Specification), Section 10 Notifications (Eventing)
document for the complete information on the WS Eventing protocol. The Lifecycle Controller related jobs are described
in the DCIM Job Control Profile document.
Alerts Message IDs
The following table provides the list of message IDs that are displayed for the alerts.
Table 23. Alert Message IDs
Message ID Description
AMP Amperage
ASR Auto Sys Reset
BAR Backup/Restore
BAT Battery Event
BIOS BIOS Management
BOOT BOOT Control
CBL Cable
163