Tus neeg siv phau ntawv
6
2. ADVANCED SETTINGS
It is possible to connect many repeaters in a chain. In order to register another repeater, follow these steps:
1. Connect the first RP-4 to the power supply socket.
2. Press the registration button on the first RP-4 – the control lights are flashing clockwise.
3. Press the registration button on the transmitting device (EU-C-8r room sensor or room regulator etc.)
4. Once steps 2 and 3 have been performed properly, the device animation will change - the control lights will start
flashing anti-clockwise.
5. Connect the second RP-4 to the power supply socket.
6. Press the registration button on the second RP-4 – the control lights are flashing clockwise.
7. Once steps 5 and 6 have been performed properly, the second device animation will change after a few seconds -
the control lights will start flashing anti-clockwise, and the control lights on the first RP-4 will be flashing
simultaneously for 5 seconds.
8. Start the registration process on the receiving device (e.g. external controller/Wi-Fi 8s / ST-2807 / ST-8s etc.)
9. If the registration has been successful, the receiving controller will display an appropriate message to confirm and
all the control lights on the second RP-4 will be flashing simultaneously for 5 seconds.
In order to register another device, follow the same steps.
NOTE
In the case of battery-powered devices, it is not advisable to create chains consisting of more than two
repeaters.
IV. TECHNICAL DATA
Specification
Value
Supply voltage
230V +/-10% / 50Hz
Operation temperature
5°C - 50°C
Maximum power consumption
1W
Frequency
868MHz
Max. transmit power
25mW