Technical Specifications

tecspecialty.com
H.B. Fuller Construction Products Inc.
1105 South Frontenac Street
Aurora, IL 60504-6451
TEC
®
1Flex
®
Fast Set Accelerated Crack Isolation Mortar Product Data
©Copyright 2013 H.B. Fuller Construction Products Inc.
TEC
®
, 1Flex
®
Fast Set, EZ Level
®
and AccuColor EFX
®
are trademarks of
H.B. Fuller Construction Products Inc. DS1FlexFS R0513-1
4. TECHNICAL DATA
Applicable Standard
Exceeds ANSI A118.4, A118.11 and A118.15 specifications
1Flex
®
Fast Set Accelerated Crack Isolation Mortar (TA-332)
Description
ANSI Requirement
Typical Results
Open Time at Room Temperature ≥ 50 minutes 30-40 minutes
Adjustability at Room Temperature ≥ 30 minutes 35-45 minutes
Final Set 9-15 hours 3-4 hours
Flexibility (movement absorbed before shear)
Quarry to Concrete
No ANSI spec
currently available
1
4
inch (6 mm)
Bond Strength
Quarry to Concrete
Procelain to Concrete
No ANSI spec
currently available
No ANSI spec
currently available
375-475 psi
(2.6-3.2 MPa)
475-485 psi
(3.2-3.3 MPa)
28 Day Shear Strength
Quarry Tile to Plywood
150 psi (1.0 MPa) 300-325* psi
(2.0-2.2 MPa)
*Plywood laminates
typically failed over
325 psi (2.2 MPa).
Greater than: > Greater than or equal to: ≥ Less than: < Less than or equal to: ≤
Physical Properties
Description
Physical State Dry powder
Color Available in white
Pot Life 45-75 minutes
Initial Cure [at 72°F (22°C) 4 to 5 hours
Final Cure 28 days
Foot Traffic Rating (ASTM C627)
Residential to Extra Heavy Commercial
(depending on substrate)
Storage
Store in cool, dry location. Do not store open
containers.
Shelf Life
Maximum 1 year from date of manufacture in
properly stored, unopened package.
5. INSTALLATION INSTRUCTIONS
Mixing
For best results, all tiling materials, substrates, room and adhesive should be at
55°-90°F (13-32°C) for 24 hours before and 48 hours after installation.
1Flex
®
Fast Set White: Add 1 gallon of water (3.78 L) to a clean mixing
container. Place drill and paddle mixer in the container and add one 35 lb.
(15.88 kg) bag of mortar. Mixing works best by adding half of bag, mix, then add
additional mortar, mix, etc. Mix material to a thick, creamy consistency. Avoid
breathing dust and contact with eyes and skin. Avoid using high speed mixing (not
to exceed 300 rpm) to prevent entraining air. A small amount of additional water
may be added to achieve proper consistency, up to 8 oz. (237 mL). Ready to use
after mixing.
Application
Apply mortar using flat side of trowel to promote better substrate contact, then
comb in one direction with the notched side of the trowel. Spread only an area
that can be tiled while surface is still tacky (typically 20-30 minutes). Press tiles
into setting bed, then push in a direction perpendicular to the notched trowel
ridges to achieve optimum coverage. Apply mortar in a heavy enough layer so that
complete contact (no voids) between mortar and tile is accomplished when tile is
positioned. It may be necessary to “back-butter” large tiles to achieve complete
coverage and firm support. Periodically remove and check a tile to assure proper
coverage. Keep a minimum of
2
3
of the joint depth between tiles for grouting.
Average pot-life of 1Flex
®
Fast Set mortar is 45-75 minutes. Stir occasionally
during use to maintain the smooth, creamy consistency of the product. Do not
add additional water.
Clean-up
Clean tools, hands, and excess materials from face of tile immediately (while
mortar is still fresh) with warm soapy water. Material that is cured is difficult or
impossible to remove.
Grouting/Curing
Grouting may be accomplished when tiles are held firmly in place, typically 4
hours after installation is completed. No traffic is permitted over the tiles prior to
grouting. Cold temperatures or high humidity may extend curing time. The use of
TEC
®
brand grouts is highly recommended.
6. AVAILABILITY AND COST
Availability
TEC
®
Premium Tile and Stone Installation Products are available nationwide. To
locate a distributor in your area, please contact:
Phone: 800-832-9002
Website: tecspecialty.com
Cost
Contact your local TEC
®
Distributor.
7. WARRANTY
For warranty details, see your sales associate or tecspecialty.com.
8. MAINTENANCE
Not applicable
9. TECHNICAL SERVICES
Technical assistance
Information is available by calling the Technical Support Hotline.
Toll Free: 800-832-9023
Fax: 630-952-1235
Technical and safety literature
To acquire technical and safety literature, please
visit our website at tecspecialty.com.
10. FILING SYSTEM