Technical Specifications

Application
Apply when air temperature is between 50°F (10°C) and 90°F (32°C) within
24 hours of application. Close all windows, doors and HVAC vents to minimize
air flow. Divide the areas to permit continuous placement without cold joints.
Pour or pump the blended Level Set
®
500 HF onto the floor and disperse with a
gauge rake. Optimum results can be obtained by providing a continuous wet flow
throughout the application. Level Set
®
500 HF has a working time 40-60 minutes
at 70°F (21°C). Temperature and humidity will affect flow, working time and
set time. Verify that the minimum depth of pour is at least
1
/
16
" over the highest
point of floor. Minimum depth of
1
/
8
" (3 mm) is required for heavy rolling loads.
Maximum Level Set
®
500 HF thickness is 2" (50 mm) neat.
Curing
Protect from excessive temperature, air movement and direct sunlight during
cure. Turn off all HVAC systems whenever possible for up to 24 hours after
installation.
NOTE: Level Set
®
500 HF is not a wearing surface and should be protected from
construction trade traffic until the final floor covering is applied.
Clean-up
While material is still fresh, clean tools, hands and equipment with warm soapy water.
6. AVAILABILITY
TEC
®
premium surface preparation, tile, stone, carpet, wood and resilient floor
covering installation products are available nationwide. To locate TEC
®
products in
your area, please contact:
Phone: 800-832-9002
Website: tecspecialty.com
7. LIMITED WARRANTY
The product(s) covered by this Product Data Sheet are sold subject to a Limited Warranty
and related terms. H.B. Fuller Construction Products disclaims the implied
warranties of merchantability and fitness for a particular purpose and all
incidental and consequential damages arising out of the sale, purchase or use
of this product. For Limited Warranty details visit tecspecialty.com. To obtain a hard copy
of the Limited Warranty call H.B. Fuller Construction Products at 800-832-9023 or mail a
written request to the address in Section 2 of this Product Data Sheet.
8. MAINTENANCE
Not applicable
9. TECHNICAL SERVICES
Technical and safety literature
To acquire technical and safety literature, please visit our website at
tecspecialty.com.
10. FILING SYSTEM
Divisions 3 and 9
©Copyright 2020 H.B. Fuller Construction Products Inc. TEC
®
, TEC
®
logo, Level Set
®
, LiquiDam
, LiquiDam EZ
and VersaPatch
®
are trademarks of H.B. Fuller Construction Products Inc.
LEED
®
is a registered trademark of U.S. Green Building Council.
DS500 R1120-20
TEC
®
Level Set
®
500 HF Self-Leveling Underlayment Product Data
Conforms with LEED v4 low emitting interiors.
Compliant with (CDPH) Standard Method v1.2 VOC Emissions.