Technical Specifications

TEC
®
Ultimate 6 Plus Mortar Product Data
Glass Tile Installation
TEC
®
Ultimate 6 plus, with its proprietary formulation, has been tested and approved to
be used with glass tile for the following applications:
1. Indoor applications only
2. Wall applications only
3. Intermittent water exposure (not for use with submerged applications).
Example such as:
a. Kitchen Backsplash
b. Shower wall accents
Note: When installing clear glass tile over waterproof membranes, visible mortar
shadowing may occur.
The Materials approved are as follows
1. Clear Glass tiles with no backing with maximum area of 16 in
2
2. 12" x 12" Matted Mosaic Tiles with clear or painted Mesh backing
3. 12" x 12" Matted Subway Tiles with Mesh backing
4. Glass tiles with painted backing up to 16 in
2
NOTE: Not all coatings used to colorize the back of glass tile are compatible with Portland
cement based mortars. Please check with the manufacturer to determine if it will be
compatible. For any questions on this, please call our Technical Support Hotline at
1-800-832-9023 for additional support.
Also, if you are looking to install a specific tile not listed in the above material list and
would like to use Ultimate 6 plus Mortar, please contact our Technical Support Hotline at
800-832-9023 for additional support.
In specifying a setting system for the bonding of glass tile, the following issues must be
taken into consideration:
Glass Tile Type: Glass tile can be manufactured in a number of different ways such as
clear, translucent with a colored body, or translucent with a colored backing. Each type
has a different aesthetic appearance. The color and composition of the mortar can have
an effect on the final appearance, especially with clear or translucent tile
Storage
Store in cool, dry location. Do not store open containers.
Shelf Life
Maximum of 1 year from date of manufacture in unopened package.
Limitations
Not for installing green marble or other moisture-sensitive stone tile; use TEC
®
AccuColor EFX
®
Epoxy Grout and Mortar.
For resin-backed marble see the TEC
®
Technical Bulletin “Installation Of Resin Backed
Stone Tiles” at tecspecialty.com.
Not for use over rubber, strip wood floors, oriented strand board, particle board, lauan
plywood.
For CDX plywood, use TEC
®
Super Flex
mortar or TEC
®
XtraFlex
acrylic mortar
additive with TEC
®
Full Set Plus
®
thin set mortar.
Do not apply over single layer wood floors.
Temperature of area to be tiled must remain above 50°F (10°C) for 72 hours.
Certain natural stone tiles may be affected by mortar shadowing or staining. Test a small
area prior to use to determine suitability.
Cautions
Read complete cautionary information printed on product container prior to use.
For medical emergency information, call 1-888-853-1758.
This Product Data Sheet has been prepared in good faith on the basis of information
available at the time of publication. It is intended to provide users with information about
and guidelines for the proper use and application of the covered TEC
®
brand product(s)
under normal environmental and working conditions. Because each project is different,
H.B. Fuller Construction Products Inc. cannot be responsible for the consequences of
variations in such conditions, or for unforeseen conditions.
4. TECHNICAL DATA
Physical Properties
Description
Physical State Dry powder
Color White
Pot Life 2 to 3 hours
Initial Cure [at 72°F (22°C)] 6 hours
Final Cure 21 days
Foot Traffic Rating (ASTM C627)
Residential to Extra Heavy Commercial
(depending on substrate)
Storage
Store in cool, dry location. Do not store open
containers.
Shelf Life
Maximum 1 year from date of manufacture in
properly stored, unopened package.
5. INSTALLATION INSTRUCTIONS
Mixing
For best results, maintain all tiling materials, substrates, room and adhesives at 50°-70°F
(10-21°C) for 24 hours before and 48 hours after installation. In a clean mixing container,
add TEC
®
Ultimate 6 Plus to clean, cool water as specified in the chart.
Application Water
LHT, Gauged Porcelain Tile Panels/Slabs
or Wall Applications
6 to 6
1
2
quarts (5.6 to 6.1 L)
Thin Set Floor Applications 6
1
2
to 6
3
4
quarts (6.1 to 6.4 L)
Add clean, cool water to a clean mixing container. Add
2
/
3
bag of TEC
®
Ultimate 6 Plus and
mix until all powder is consumed. Add final
1
/
3
bag and mix until powder is consumed. Be
cautious not to over-water. Consistency will loosen during mixing process. Mix material for
two (2) minutes to a smooth and creamy consistency. Avoid breathing dust and contact
with eyes and skin. Allow the mortar to stand for 10 minutes. Remix and apply. Avoid
using high speed mixing, not to exceed 300 rpm, to prevent entraining air.
Application
Apply mortar using flat side of trowel to promote better substrate contact, then comb in
one direction with the notched side of the trowel. Spread only an area that can be tiled
while surface is still tacky (typically 20-30 minutes). Press tiles into setting bed, then push
in a direction perpendicular to the notched trowel ridges to achieve optimum coverage.
Apply mortar in a heavy enough layer so that complete contact (no voids) between mortar
and tile is accomplished when tile is positioned. Irregularities in substrate may require
"back-buttering" of large tiles to achieve complete coverage and firm support. Periodically
remove and check a tile to assure proper coverage. Keep a minimum of
2
3
of the joint
depth between tiles for grouting. Open time and tile hand adjustability may vary with job
site conditions. Stir occasionally during use to maintain the smooth, creamy consistency of
the product. Do not add additional water.
Applicable Standard
Exceeds ANSI A118.4E and A118.11 specifications
ISO 13007: Classification C2TEP1
TEC
®
Ultimate 6 Plus (487)
ANSI Standard Test Section Test Duration/Conditions ANSI Specification Typical Results
A118.11 Shear Strength to Quarry Tile 4.1.2 28 day plywood >150 psi (10.5 kg/cm
3
) 220
A118.4 Glazed Wall Tile Shear Strength
Porcelain Mosaic Tile Shear Strength
Quarry Tile Shear Strength
7.1.2
7.2.5
7.3.2
7 day
28 day
28 day
>300 psi (2.07 MPa)
>200 psi (1.38 MPa)
150 psi (1.03 MPa)
545
480
400
A118.4E Open Time 5.3.6 30 minute 75 psi (0.5 MPa) at 30 minutes 185
Greater than: > Greater than or equal to: ≥ Less than: < Less than or equal to: ≤