Instruction manual
www.teamorion.com 25
VERFÜGBARE EINSTELLUNGEN UND STANDARDWERTE
Parameter
(indicated by
green LED )
Setting (indicated by red LED )
1 2 3 4 5 6 7 8 9
Standard Parameters (adjustable with on/o switch)
1 Running
Mode
Forward
with
Brake
Forward/
Reverse
with
Brake
Foward/
Reverse
(For
Rock
Crawler)
2 Drag Brake
Force 0% 5% 10% 20% 25% 30% 100%
User set
in 1%
steps
3 Low Voltage
Cut-O
Threshold
No
Protection
2.6V/Cell
2.8V/
Cell
3.0V/
Cell
3.2V/Cell 3.4V/Cell
User set
in 0.1V
steps
4 Start Mode
(Punch)
Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7
Level
8
Level 9
5 Max Brake
Force
25% 50% 75% 100% Disable
6 Max Reverse
Force
25% 50% 75% 100%
7 Initial Brake
Force
Drag
Brake
Force
0% 20% 40%
8 Neutral
Range
6%
(Narrow)
9%
(Normal)
12%
(Wide)
9 Timing 1 2 3 4 5 6 7 8
12 Motor
Rotation
Direction
CCW CW
13 LiPO Cells Auto 2S 7.4V 3S 11.1V 4S 14.8V 5S 18.5V 6S 22.2V
14 BEC Voltage 6V 7.2V