TBS Tracer Manual

General functions
Binding
Binding a receiver to your Tracer is an easy task and does not require 3 hands or any special jumpering.
General note on model match
You will notice that you can control any r/c model, even if you changed the model in your radio*. This is
due to the Tracer not performing a model match the radio model. You have to make sure that you selected
the right model in your radio before you power up the receiver.
If you are used to FrSky, it’s the same behavior as when you set your receiver number to 00 in the mode
settings (with FrSky receivers).
If you want to make sure that a certain OpenTX model only binds to a specific receiver, you can change the
model number to a unique ID before binding. In this case, having the wrong model selected in OpenTX will
mean the model will not bind. This is a safety precaution that we recommend for models that do not have
a flight controller governing the electric power drive.
*Model matching with the Tracer and OpenTX is available since OpenTx 2.3.10
When do i need to bind again
There are only a few cases when you need to rebind your transmitter to the receiver:
You updated your transmitter firmware
You enabled multi-bind*
You did a factory-reset on the receiver
You are using a different Tracer TX with your receiver, without multi-bind
You changed the model id/ receiver number in Opentx*
* you can avoid a rebind, if you change these settings while the receiver is bound and powered up.
Binding issue - Double green flashing
If you get a double green flashing pattern on the receiver for several seconds after updating or binding,
you got an authentication error. To solve this issue:
Shut down the receiver
Set the Tx in bind mode
Power up the receiver
Push the
Bind
button on the Rx
After the binding the pattern may return but should be gone after a few seconds.