Datasheet
Coil Data (values at 23°C)
Nominal Operate/set voltage range Release/ Nominal power Resistance Coil number
voltage reset voltage consumption
Unom Minimum Maximum Minimum
voltage U
I
voltage U
II
Vdc Vdc Vdc Vdc mW W / ± 10 %
1.5 1.3 2.6 0.15 375 6 001
3 2.1 4.7 0.30 450 20 002
5 3.5 7.9 0.50 446 56 003
6 4.2 9.5 0.60 450 80 004
9 6.3 14.2 0.90 450 180 005
12 8.4 19.0 1.20 450 320 006
24 16.8 38.0 2.40 450 1280 007
450 mW nominal power consumption
1.5 1.1 3.6 0.15 188 12 101
3 2.3 7.1 0.30 200 45 102
5 3.8 11.6 0.50 208 120 103
6 4.5 14.2 0.60 200 180 104
9 6.8 21.2 0.90 203 400 105
12 9.0 28.0 1.20 206 700 106
24 18.0 56.0 2.40 206 2800 107
200 mW nominal power consumption
W11 Relay V23101
4
Ambient temperature t
amb
[°C]
U
I
= Minimum voltage at 23° C after pre-energizing
with nominal voltage without contact current
U
II
= Maximum continous voltage at 23°
The operating voltage limits U
I
and U
II
depend on
the temperature according to the formula:
U
I tamb
=K
I
· U
I 23° C
and
U
II tamb
=K
Il
· U
Il 23° C
t
amb
= Ambient temperature
U
I tamb
= Minimum voltage at ambient temperature, t
amb
U
II tamb
= Maximum voltage at ambient temperature, t
amb
k
I
, k
II
= Factors (dependent on temperature), see diagram